Overview
UHP-200R-15 is the 15V output model of this series: rated current 13.4A, rated power 201W, typical efficiency 94%.
UHP-200 series is a 200W single-output slim type power supply with 26mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V,48V and 55V . In addition to the high efficiency up to 94%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-200 has the complete protection functions and 5G anti-vibration capability;It is complied with the international safety regulations such as TUV BS EN/EN62368-1,BS EN/EN60335-1,UL 62368-1 and GB 4943.1. UHP-200 series serves as a high performance power supply solution for various industrial applications.
Features
- Slim and Low profile (26mm)
- Fanless design,200W convection
- Withstand 300VAC surge input for 5 seconds
- Built-in active PFC function
- -30~+70℃ working temperature
- Protections: Short circuit / Overload / Over voltage / Over temperature
- DC OK active signal and redundant function(option)
- Operating altitude up to 5000 meter (Note.5)
- LED indicator for power on
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 13.4A
- RATED POWER
- 201W
- RIPPLE & NOISE (max.)Note.2
- 240mVp-p
- VOLTAGE ADJ. RANGE
- 14.3~15.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 2000ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load;550ms/230VAC for 55V setup time
- HOLD UP TIME (Typ.)
- 10ms/230VAC 10ms/115VAC
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≥0.94/230VAC PF≥0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 94%
- AC CURRENT (Typ.)
- 2.2A/115VAC 1.1A/230VAC
- INRUSH CURRENT (Typ.)Note.8
- Cold start 40A/115VAC 80A/230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVERLOAD
- 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 16.5 ~ 19.5V Protection type :Shut down O/P voltage,re-power on to recover
- OVER TEMPERATURE
- Protection type :Shut down O/P voltage or Hiccup mode, recovers automatically after temperature goes down
FUNCTION
- DC OK SIGNAL(Optional)
- Contact rating(max.):15Vdc/10mA resistive load
- REDUNDANT(Optional)
- For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃(Refer to “Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.6)
- SAFETY STANDARDS
- UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), GB 4943.1, EAC TP TC 004, KC62368-1(only for UHP-200-24), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10), BS EN/EN61558-1,BS EN/EN61558-2-16,BSMI CNS15598-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
- EMC EMISSION
- Compliance to BS EN/EN55032,GB17625.1,GB/T 9254.1,Class B, BS EN/EN55014,BS EN/EN61000-3-2,-3, EAC TP TC 020,BSMI CNS15936
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level ,EAC TP TC 020
OTHERS
- MTBF
- 2472.1 K hrs min. Telcordia SR-332 (Bellcore) ; 257.0K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 194*55*26mm (L*W*H)
- PACKING
- 0.468kg;24pcs/12.2kg/0.49CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft)
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. R type efficiency slightly less than the Blank type, according to the actual measurement.
- 8. Inrush current parameter has 10% tolerance .
- 9. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 10. Some models or factory may not have the BIS marking , please contact MEAN WELL’s sales for more details.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
- LED display application
- Power Source Equipment for PoE(55V model)
Downloads
Certificates10
Test reports1
FAQ
Can I use the UHP-200R-15 for 15V industrial electronics or test equipment?
Yes, if the equipment requires a constant voltage 15V source and the load stays within 201W and 13.4A. This makes it a fit for 15V DC industrial electronics and bench or rack equipment built around that voltage.
Is the UHP-200R-15 appropriate for a monitored 15V control system?
Yes, the built-in DC OK and redundant function are the main reasons to choose this version for a monitored 15V system. It combines those features with a 15V, 201W, 13.4A output in a slim fanless package.
Can this 15V model be used in embedded or OEM equipment with limited space?
It can be a good fit where a 15V constant voltage supply is required and output demand remains within 13.4A. The 194 × 55 × 26 mm dimensions and fanless design support compact protected enclosures.
Would the UHP-200R-15 work for 15V instrumentation or panel subsystems that need redundancy features?
Yes, that is a reasonable use case if the subsystem runs on 15V DC and draws no more than 201W. The redundant function and DC OK feature distinguish it from a basic 15V supply when uptime monitoring is part of the requirement.
Is the UHP-200R-15 rated for outdoor conditions?
The specified operating temperature range is -30°C to +70°C. The provided specs do not state an IP rating, so outdoor, washdown, or direct-weather use is not defined by the listed data.
How does the UHP-200R-15 compare with the other UHP-200R redundant models?
The UHP-200R family includes 3.3V at 132W and 40A, 4.2V at 168W and 40A, 5V at 200W and 40A, 12V at 200.4W and 16.7A, 24V at 201.6W and 8.4A, 36V at 201.6W and 5.6A, and 48V at 201.6W and 4.2A. The UHP-200R-15 is the 15V version, rated 201W and 13.4A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.