UHP-1000-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 95%.
UHP-1000 series is a 1000W single-output slim type power supply with 41mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 12V,24V,36V and 48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-1000 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1. UHP-1000 series serves as a high performance power supply solution for various industrial applications.
Features
- Slim and Low profile (41mm)
- Fanless and conduction-cooled design
- Withstand 300VAC surge input for 5 seconds
- Built-in active PFC function
- -30~+70℃ working temperature
- Output voltage and constant current level programmable
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in remote ON-OFF control
- DC OK active signal
- Operating altitude up to 5000 meter (Note.7)
- LED indicator for power on
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 42A
- RATED POWER
- 1008W
- RIPPLE & NOISE (max.)Note.2
- 240mVp-p
- VOLTAGE ADJ. RANGE
- By built-in potentiometer, SVR
- VOLTAGE ADJ. RANGE
- 24~28.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.4
- 1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 12ms/230VAC 12ms/115VAC
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 250 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)Note.4
- PF≥0.95/230VAC PF≥0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 95%
- AC CURRENT (Typ.)
- 10.1A/115VAC 5.3A/230VAC
- INRUSH CURRENT (Typ.)
- Cold start 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVERLOAD
- 105~120% rated output power Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover
- SHORT CIRCUIT
- Protection type: Constant current limiting with delay shutdown after 3 seconds, re-power on to recover
- OVER VOLTAGE
- 29 ~ 33V Protection type: Shut down O/P voltage, re-power on to recover
- OVER TEMPERATURE
- Protection type: Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note 5
- Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage Please refer to the Function Manual.
- OUTPUT CURRENT PROGRAMMABLE(PC)Note 5
- Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
- REMOTE ON/OFF CONTROL
- Power ON: "Low" <0 ~ 0.5V or Short circuit Power OFF: "Hi" >2 ~ 5V or Open circuit
- AUXILIARY POWER
- 12V@0.5A tolerance±10%, ripple 150mVp-p
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = 4.5 ~ 5.5V; PSU turn off = -0.1 ~ 0.5V. Please refer to the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃(Refer to “Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P: 3.75KVAC I/P-FG: 2KVAC O/P-FG: 1.25KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/500VDC/25℃/ 70%RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 662.3K hrs min. Telcordia SR-332 (Bellcore) ; 69.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 240*115*41mm (L*W*H)
- PACKING
- 1.74kg ; 8pcs/14.9kg/0.74CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance: includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve and Static characteristics for more details.
- 5. PV/PC functions when users do not use SVR.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. " (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- Household appliances
- Power Sourcing Equipment of PoE (48V model: DC O/P range 48~57.6V)
Downloads
Certificates5
Test reports1
FAQ
Can I use the UHP-1000-24 for a 24V industrial control or automation load?
Yes, if the system is designed for 24V constant-voltage power and the load stays within 1008W and 42A. That output level fits heavier 24V automation or control applications than smaller 24V supplies in the same series.
Is the UHP-1000-24 suitable for 24V embedded or IT equipment with a wide AC input range?
The input range is 90-264VAC, which supports use across a broad AC input window. On the DC side, it delivers 24V constant-voltage output with up to 42A and 1008W available.
Can the UHP-1000-24 power a larger 24V DC bus for centralized equipment power?
This model is built for higher-capacity 24V distribution because it provides 1008W total power at 24V and 42A. It is appropriate when the connected 24V loads together remain within those ratings.
How does the UHP-1000-24 compare with the other UHP-1000 voltage options?
The UHP-1000-12 is rated 960W, 12V, 80A; the UHP-1000-24 is 1008W, 24V, 42A; the UHP-1000-36 is 1008W, 36V, 28A; and the UHP-1000-48 is 1008W, 48V, 21A. They share the same listed 90-264VAC input, 240 x 115 x 41 mm size, 1.74 kg weight, -30 C to +70 C operating range, UL62368-1/TUV/EN62368-1/EAC certifications, 5-year warranty, and slim fanless low-profile form factor.
Can the UHP-1000-24 be used in hot equipment rooms or cold indoor industrial spaces?
The specified operating temperature range is -30 C to +70 C, so it is rated for both cold and warm indoor environments within that band. Since no IP rating is provided, the product data does not establish direct outdoor suitability.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.