Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well RSP-3000-48 Power Supply 3000W 48V 62.5A

built-in active PFChigh efficiency up to 91.5%active current sharing(2+1)
SKU RSP-3000-48
$548.68 USD
Shipping calculated at checkout.
Model

Select model — 12 in this family

RSP-3000-48
In stock
|

Overview

RSP-3000-48 is the 48V output model of this series: rated current 62.5A, rated power 3000W, typical efficiency 91.5%.

RSP-3000 is a 3KW single output enclosed type AC/DC power supply. This series operates for 180~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70℃. Moreover, RSP-3000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.

Features

  • AC input 180~264VAC
  • Built-in active PFC function
  • High efficiency up to 91.5%
  • Forced air cooling by built-in DC fan
  • Output voltage programmable
  • Active current sharing up to 9000W (2+1)
  • Built-in remote ON-OFF control / remote sense / auxiliary power / power OK signal
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional conformal coating
  • 5 years warranty

Specifications

RSP-3000-48Specifications from the official datasheet (2026-07-20 edition)

OUTPUT

DC VOLTAGE
48V
RATED CURRENT
62.5A
CURRENT RANGE
0 ~ 62.5A
RATED POWER
3000W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
43 ~ 56V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 80ms at full load
HOLD UP TIME (Typ.)
10ms at full load

INPUT

VOLTAGE RANGE
180 ~ 264VAC 254 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.95/230VAC at full load
EFFICIENCY (Typ.)
91.5%
AC CURRENT (Typ.)
20A/180VAC 16A/230VAC
INRUSH CURRENT (Typ.)
60A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC

PROTECTION

OVERLOAD
100 ~ 112% rated output power User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover
OVER VOLTAGE
57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

OUTPUT VOLTAGE PROGRAMMABLE(PV)
9.6 ~ 56V Please refer to the Function Manual.
CURRENT SHARING
Up to 9000W or (2+1) units. Please refer to the Function Manual.
AUXILIARY POWER(AUX)
12V@0.1A(Only for Remote ON/OFF control)
REMOTE ON-OFF CONTROL
Please refer to the Function Manual
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual.
ALARM SIGNAL OUTPUT
Power OK signal. Please refer to the Function Manual

ENVIRONMENT

WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.05%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, IS13252(Part1)/IEC60950-1 (except for 48V), EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/ EN55032 (CISPR32), CNS15936Class B
RadiatedBS EN/ EN55032 (CISPR32), CNS15936Class A
Harmonic CurrentBS EN/ EN61000-3-2
Voltage FlickerBS EN/ EN61000-3-3
EMC IMMUNITY

BS EN/ EN55035, BS EN/ EN61000-6-2, BSMI CNS13438

ParameterStandardTest Level
ESDBS EN/ EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/ EN61000-4-3Level 3
EFT / BurstBS EN/ EN61000-4-4Level 3
SurgeBS EN/ EN61000-4-5Level 3, 2KV/Line-Earth; Level 2, 1KV/Line-Line
ConductedBS EN/ EN61000-4-6Level 3
Magnetic FieldBS EN/ EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/ EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
677.3K hrs min. Telcordia SR-332 (Bellcore) ; 75.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
278*177.8*63.5mm (L*W*H)
PACKING
4Kg; 4pcs/16Kg/2.04CUFT
Test conditions and notes5
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  5. 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RSP-3000-48 Block Diagram
Block Diagram
RSP-3000-48 Static Characteristics
Static Characteristics
RSP-3000-48 Function Manual
Function Manual
RSP-3000-48 R S P - 3 0 0 0 series
R S P - 3 0 0 0 series
RSP-3000-48 Example 3.2(A): Using external voltage source
Example 3.2(A): Using external voltage source
RSP-3000-48 Example 3.2(B): Using internal 12V auxiliary output
Example 3.2(B): Using internal 12V auxiliary output
RSP-3000-48 ◎ Connection Method
◎ Connection Method
RSP-3000-48 ◎ By factory default, OLP(PIN9) and OL-SD(PIN10)
◎ By factory default, OLP(PIN9) and OL-SD(PIN10)
RSP-3000-48 ◎ By factory default, OLP(PIN9) and OL-SD(PIN10) (2)
◎ By factory default, OLP(PIN9) and OL-SD(PIN10) (2)
RSP-3000-48 R S P - 3 0 0 0 series
R S P - 3 0 0 0 series
RSP-3000-48 R S P - 3 0 0 0 series (2)
R S P - 3 0 0 0 series (2)
RSP-3000-48 7.Three Phase Connect
7.Three Phase Connect
RSP-3000-48 FIG. B: 3ψ4W 220/380VAC SYSTEM
FIG. B: 3ψ4W 220/380VAC SYSTEM
RSP-3000-48 FIG. C: 3ψ4W 190/110VAC SYSTEM
FIG. C: 3ψ4W 190/110VAC SYSTEM
RSP-3000-48 Mechanical Specification
Mechanical Specification
RSP-3000-48 ※Control Pin No. Assignment (CN3) : HRS DF11-10DP-2DS or…
※Control Pin No. Assignment (CN3) : HRS DF11-10DP-2DS or…

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • Digital broadcasting
  • RF application

Downloads

FAQ

What is the RSP-3000-48 used for in data center or telecom environments?

The RSP-3000-48 supplies 3000W at 48V with 62.5A output, suitable for factory control, automation, and test equipment. Its 5-year warranty and broad certification set (UL, CSA, TUV, BSMI, AS/NZS, EAC) support industrial deployments.

What temperature range does the RSP-3000-48 support?

The RSP-3000-48 is rated for -20°C to +70°C ambient operation. It is intended for indoor enclosed use only and does not carry an IP rating for outdoor environments.

How does the RSP-3000-48 compare to the RSP-2400-48 and RSP-2000-48?

The RSP-3000-48 provides 3000W and 62.5A. The RSP-3000-24 also provides 3000W but at 125A, while the RSP-3000-12 is rated for 2400W at 200A. All models in this series share the same 180-264VAC input range and 4kg weight.

What paralleling configuration does the RSP-3000-48 support?

The RSP-3000-48 supports active current sharing up to 9000W or (2+1) units. Two units in parallel deliver up to 125A at 48V, with a third unit providing N+1 redundancy. Efficiency reaches up to 91.5%.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other RSP-3000 Models

1 other model
ModelPowerVoltageCurrent
Mean Well RSP-3000-24 Power Supply 3000W 24V 125A 3000W 24V 125A View
{ "id":8920270635328, "variants" :[{ "context":"default", "variant_id": 47365737840960, "sku":"RSP-3000-48", "inventory_qty" : 83, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$548.68\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RSP-3000-48 Power Supply 3000W 48V 62.5A
Mean Well

Mean Well RSP-3000-48 Power Supply 3000W 48V 62.5A

$548.68 USD

RSP-3000-48 is the 48V output model of this series: rated current 62.5A, rated power 3000W, typical efficiency 91.5%.

RSP-3000 is a 3KW single output enclosed type AC/DC power supply. This series operates for 180~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70℃. Moreover, RSP-3000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.

Features

  • AC input 180~264VAC
  • Built-in active PFC function
  • High efficiency up to 91.5%
  • Forced air cooling by built-in DC fan
  • Output voltage programmable
  • Active current sharing up to 9000W (2+1)
  • Built-in remote ON-OFF control / remote sense / auxiliary power / power OK signal
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional conformal coating
  • 5 years warranty

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • Digital broadcasting
  • RF application

Model

  • 75W 48V
  • 100W 48V
  • 150W 48V
  • 320W 48V
  • 500W 48V
  • 750W 48V
  • 1000W 48V
  • 1500W 48V
  • 1600W 48V
  • 2000W 48V
  • 2400W 48V
  • 3000W 48V
View product