Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MSP-1600-48 is the 48V output model of this series: rated current 33.5A, rated power 1608W, typical efficiency 92%.
The MSP-1600 series is a 1600W AC/DC power supply with PFC function, designed for high reliability and suitable for multiple industries. Key features include: compact size (310*85*41mm) for better space utilization in system installations, ultra-wide input range of 85~264Vac for global compatibility, up to 92% efficiency, programmable output voltage (15~115%), built-in CANBus communication interface, wide operating temperature range from -40 to +85℃ (+50℃ at full load), compliance with OVCⅢ, built-in Remote Control/Remote Sense/DC OK signal/auxiliary power, internal PCB coating, complete protections, certifications for multiple safety standards including 62368-1, 60601-1, 61558-1, 60335-1, 62477-1, and 61010-1, as well as 2 X MOPP compliance and extremely low leakage current (<500μA). It is suitable for BF-rated medical equipment and comes with a 5-years warranty, making it a highly cost-effective solution for industrial power supply needs.
Features
- 85~264Vac input with PFC
- Global certificates in multi-fields(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16/61010-1, Energy converter 62477-1)
- High efficiency up to 92%
- Output voltage 15 ~115% programmable
- Built-in CANBus protocol
- -40~+85℃ wide range operation temperature
- Extremely low leakage current <500μA, 2 x MOPP, suitable for BF medical applications
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in Remote ON/OFF control / Remote Sense / DC OK signal / OTP alarm signal /Auxiliary 12Vdc
- Over voltage category Ⅲ (OVC Ⅲ)
- Operating altitude up to 5000 meters
- Built-in intelligent fan speed control, low noise <43dB
- Conformal coating
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 33.5A
- CURRENT RANGE
- 0 ~ 33.5A
- RATED POWER
- 1608W
- RIPPLE & NOISE (max.)Note.2
- 300mVp-p
- VOLTAGE ADJ. RANGE
- 47.5 ~ 56V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.4
- 1500ms, 60ms/230Vac at full load
- HOLD UP TIME (Typ.)
- 16ms / 230Vac at 70% load 10ms / 230Vac at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264Vac 250 ~ 400Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.97/230Vac at full load
- EFFICIENCY (Typ.)
- 92%
- AC CURRENT (Typ.)
- 15A/115Vac 8.5A/230Vac
- INRUSH CURRENT (Typ.)
- COLD START 60A/230Vac
- LEAKAGE CURRENT
- Earth leakage current <500μA(rms)/264Vac ; Touch current<100μA(rms)/264Vac
PROTECTION
- OVERLOAD
- 105 ~ 115% rated output power Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. After O/P voltage falls, re-power on to recover
- OVER VOLTAGE
- 56 ~ 60V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note.6
- Adjustment of output voltage is allowable to 15 ~ 115% of nominal output voltage Please refer to the User Manual.
- REMOTE CONTROL
- By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the User Manual
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.5Vdc. Please refer to the User Manual
- AUXILIARY POWER
- 12Vaux @ 0.8A, tolerance: 10.6~13.2V; Ripple: 450mVp-p
- DC OK SIGNAL
- Contact rating(max.):5Vdc/10mA resistive load
- CANBus(Built-in)
- Communication provides functions such as control, setting and monitoring
- FAN NOISE (Typ.)Note.7
- Built-in intelligent fan speed control detect by PSU'S internal temperature
- FAN NOISE (Typ.) 10% load with Ta=25℃
- 39dB
- FAN NOISE (Typ.) 70% load with Ta=25℃
- 39dB
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.8~10)
- SAFETY STANDARDS
- CB IEC60335-1, IEC61558-1/-2-16, IEC61010-1/-2-201, IEC60601-1(3.2 version); IEC62477-1, IEC62368-1 ; DEKRA BS EN/EN60601-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN61010-1/-2-201, BS EN/EN62477-1 ; UL ANSI/AAMI ES60601-1(3.2 Version),UL61010-1/-2-201 ; CQC GB4943.1 ; BSMI CNS15598-1 ; EAC TP TC 004 ; SEMI F47 approved ; KC/BIS KC 62368-1 and BIS IS 13252(Part 1) certified, No stock, contact sales by request
- ISOLATION LEVEL
- Primary-Secondary: 2xMOPP, Primary-Earth: 1xMOPP, Secondary-Earth: 1xMOPP
- OVER VOLTAGE CATEGORYNote.11
- IEC/EN 61558-1/-2-16 (OVC Ⅲ , altitude up to 2000M) ; IEC 62368-1 (OVC Ⅱ, altitude up to 5000M) ; IEC/EN 60335-1 (OVC Ⅱ, altitude up to 5000M) ; IEC/EN/ANSI/AAMI ES60601-1 (OVC Ⅱ, altitude up to 4000M) ; IEC/EN/UL 61010-1/-2-201 (OVC Ⅱ, altitude up to 5000M) ; IEC/EN 62477-1 (OVC Ⅱ, altitude up to 5000M)
- SAFETY EXTRA-LOW VOLTAGE(SELV)
- IEC/EN 61558-2-16 (SELV, 12 ~ 48V) ; IEC/EN 60335-1 (SELV, 12 ~ 36V) ; IEC 62368-1 (SELV/ES1, 12 ~ 48V)
- WITHSTAND VOLTAGE
- I/P-O/P:4.2KVac I/P-FG:2.1KVac O/P-FG:1.5KVac
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832 Class B Conducted BS EN/EN55014-1(CISPR14-1) Conducted BS EN/EN55011(CISPR11) Class B Radiated BS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832 Class B Radiated BS EN/EN55014-1(CISPR14-1) Radiated BS EN/EN55011(CISPR11) Class B Harmonic Current BS EN/EN61000-3-2(IEC61000-3-2) Class A Voltage Flicker BS EN/EN61000-3-3(IEC61000-3-3) - EMC IMMUNITY
-
BS EN/EN55035(CISPR35),BS EN/EN61000-6-2(IEC61000-6-2),BS EN/EN60601-1-2(IEC60601-1-2), BS EN/EN55014-2(CISPR14-2),KS C 9835,SEMI F47 tested at 200Vac
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact Radiated BS EN/ EN61000-4-3 Level 3, 10V/m(80MHz~2.7GHz) Table 9, 9~28V/m(385MHz~5.78GHz) EFT / Burst BS EN/ EN61000-4-4 Level 3, 2KV Surge BS EN/ EN61000-4-5 Level 4, 2KV/Line-Line; 4KV/Line-Earth Conducted BS EN/ EN61000-4-6 Level 3, 10V Magnetic Field BS EN/ EN61000-4-8 Level 4, 30A/m Voltage Dips and Interruptions BS EN/ EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 653.8K hrs min. Telcordia SR-332 (Bellcore) ; 65.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION (L*W*H)
- 310*85*41mm
- PACKING
- 1.72Kg;6pcs/11.3Kg/1.28CUFT
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Setup time is measured at the first cold start.
- 5. Derating may be required at low input voltages; refer to the "Static Characteristics" section for details.
- 6. When the output voltage is adjusted via the PV function, the output ripple and noise may exceed the specified limits under certain operating conditions.
- 7. Fan noise measurement is performed in accordance with ISO 7779.
- 8. The Regulatory Compliance Mark (RCM) is applied on a voluntary basis. The equipment meets the relevant IEC or AS/NZS standards, or AS/NZS 3820 where applicable. The use of the RCM mark complies with AS/NZS 4417.1.
- 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 10. The BIS marking may not be available for certain manufacturing sites or models. Please contact your MEAN WELL sales rep for further information.
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial automation machinery/ control system
- Security system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Network equipment
- Telecom devices
- Power sourcing equipment of PoE
- Home automation
- Medical devices
- Supercapacitor
Downloads
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MSP-1600 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well MSP-1600-36 Power Supply 1602W 36V 44.5A | 1602W | 36V | 44.5A | View |
| Mean Well MSP-1600-24 Power Supply 1608W 24V 67A | 1608W | 24V | 67A | View |
| Mean Well MSP-1600-12 Power Supply 1500W 12V 125A | 1500W | 12V | 125A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.