Overview
SKE15B-24 is the 24V output model of this series: rated power 15W, typical efficiency 83%.
Features
- 2:1 wide input range
- 4:1 wide input range(option)
- 1500VDC I/O isolation
- 3000VDC I/O isolation(option)
- Built-in EMI filter
- Protections: Short circuit / Overload
- Cooling by free air convection
- Six-sided shield metal case
- 100% burn-in test
- Low cost / High reliability
- Approvals: FCC / EAC / CE / UKCA
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- CURRENT RANGE
- 62.5 ~ 625mA
- RATED POWER
- 15W
- RIPPLE & NOISE (max.)Note.2
- 80mVp-p
- LINE REGULATIONNote.3
- ±0.3%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE ACCURACY
- ±2.0%
- SWITCHING FREQUENCY
- 150KHz min.
INPUT
- VOLTAGE RANGE
- 18 ~ 36VDC
- EFFICIENCY (Typ.)
- 83%
- DC CURRENT Full load
- 800mA
- DC CURRENT No load
- 20mA
- FILTER
- Pi network
- PROTECTION
- Fuse recommended
PROTECTION (Note. 5)
- OVER CURRENT
- 160% ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +71℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -25 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 Class A, FCC part 15 Class A , EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020
OTHERS
- MTBF
- 300Khrs min. MIL-HDBK-217F(25℃)
- DIMENSION
- 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H)
- PACKING
- 60g ; 5pcs/per tube, 200pcs/40 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
FAQ
Can I use the SKE15B-24 to power 24V automation electronics from an 18-36VAC source?
Yes. This unit accepts 18-36VAC input and provides a constant 24V output with 15W total power. It is intended for 24V electronics that require regulated constant-voltage output and fit within the published power rating.
Is the SKE15B-24 suitable for compact 24V control modules or industrial interface devices?
It can be suitable for lower-power 24V control or interface electronics because it provides constant 24V output in a 15W package. The compact 50.8 × 50.8 × 11.0 mm size also helps in dense equipment layouts.
Can this converter be used in OEM machinery that distributes 18-36VAC internally but needs a 24V DC rail?
Yes, that is an appropriate use case when the downstream electronics require regulated 24V constant-voltage power. The published input range is 18-36VAC, so it is designed for equipment operating within that AC window.
Is the SKE15B-24 appropriate for 24V monitoring, signaling, or instrumentation electronics?
It can be used for 24V monitoring, signaling, or instrumentation electronics that are designed for constant-voltage input and fit within the 15W rating. As with the rest of the series, it is a compact converter intended for regulated low-power DC output.
How does the SKE15B-24 differ from the other SKE15B models?
The SKE15B-24 shares the same 15W rating, 18-36VAC input range, dimensions, and -25°C to +71°C operating range as its siblings. Output options across the family are 5V at 3A, 12V at 1.25A, 15V at 1A, and 24V at 625A for this model.
Is the SKE15B-24 meant for exposed outdoor environments?
No IP rating is listed in the provided specifications. Even though the operating temperature range is -25°C to +71°C, the lack of a stated ingress-protection rating means it is better suited to protected environments rather than exposed outdoor use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.