Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SDM30-12S3 is the 3.3V output model of this series: rated current 5A, rated power 16.5W, typical efficiency 77%.
Features
- Wide 2:1 DC input range
- In/out capacitance1000pF
- Protections: Short circuit / Overload / Over voltage
- 1000VDC I/O isolation for D/D
- Cooling by free air convection
- Built-in remote ON-OFF control
- 100% full load burn-in test
- Fixed switching frequency at 225KHz
- Low cost
- High reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 3.3V
- RATED CURRENT
- 5A
- CURRENT RANGE
- 0 ~ 5A
- RATED POWER
- 16.5W
- RIPPLE & NOISE (max.)Note.2
- 75mVp-p
- VOLTAGE TOLERANCENote.3
- ±3.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±1.0%
- TRIM OUTPUT
- ±13%(Typ.) output voltage
INPUT
- RATED DC INPUT
- 12S: 12VDC 24S: 24VDC 48S: 48VDC
- VOLTAGE RANGE
- 12S: 9.2 ~ 18VDC 24S: 18~ 36VDC 48S: 36~ 72VDC
- EFFICIENCY (Typ.)
- 77%
- DC CURRENT
- 12S:3.6A 24S:2A 48S:1A
- IDLE CURRENT
- 12S:35mA 24S/48S:30mA
PROTECTION
- OVERLOAD
- Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 3.8 ~ 4.95V Protection type : Shut off o/p voltage, clamping by zener diode
- SHORT CIRCUIT
- Protection type : Constant current limiting, recovers automatically after fault condition is removed
FUNCTION
- ON/OFF CONTROL
- Logic "1" or open: power on Logic "0" short to Vin-: power off
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +85℃ (Refer to "Derating Curve")
- STORAGE TEMP., HUMIDITY
- -25 ~ +85℃, 0 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃)
SAFETY & EMC (Note 6)
- SAFETY STANDARDS
- Design refer to LVD, EAC TP TC 004 approved
- ISOLATION VOLTAGE
- I/P-O/P:1KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃ / 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 8083.5K hrs min. Telcordia SR-332 (Bellcore) ; 777.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*50.8*16mm (2"*2"*0.63") (L*W*H)
- PACKING
- 0.1Kg; 150pcs/15.8Kg/0.94CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Short circuit not more than 60 second.
- 5. DC source wires ≧5cm, an input external al capacitor 47 ~ 100uF is required.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the SDM30-12S3 to power a 3.3V logic board or embedded controller from a 9.2-18V source?
Yes, this model is designed for constant-voltage 3.3V loads when the available input is within 9.2-18V. It can deliver up to 5A, so the connected 3.3V electronics need to stay within that output current and the 16.5W rating.
Is the SDM30-12S3 a fit for 3.3V communication modules, industrial SBCs, or processor boards?
It is a practical match for 3.3V embedded and interface hardware that needs a regulated constant-voltage rail. The 5A output makes it more suitable for current-hungry 3.3V electronics than a lower-current converter would be.
Can this converter support several 3.3V devices on one rail in an automation system?
It can, provided the combined 3.3V load stays within 5A total. That makes it usable for grouped 3.3V logic, communication, and controller loads in compact industrial or embedded systems.
Is the SDM30-12S3 suitable for outdoor equipment or wide-temperature enclosures?
The rated operating range is -25°C to +85°C, with the load derated at higher ambient temperatures per the derating curve, so it covers a broad temperature window for enclosed equipment. No IP rating is listed, so weather, dust, and water exposure need to be managed at the enclosure level.
How does the SDM30-12S3 compare with the other SDM30 converters listed here?
For the listed 12V-input models, SDM30-12S3 is 16.5W, 3.3V, 5A; SDM30-12S5 is 25W, 5V, 5A; SDM30-12S12 is 25.2W, 12V, 2.1A; and SDM30-12S15 is 25.5W, 15V, 1.7A. The other listed variants are SDM30-24S12 at 30W, 12V, 2.5A; SDM30-24S15 at 30W, 15V, 2A; SDM30-24S3 at 16.5W, 3.3V, 5A; SDM30-24S5 at 25W, 5V, 5A; SDM30-48S12 at 30W, 12V, 2.5A; SDM30-48S15 at 30W, 15V, 2A; SDM30-48S3 at 16.5W, 3.3V, 5A; and SDM30-48S5 at 25W, 5V, 5A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.