Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DDRH-120-32 is the 32V output model of this series: rated current 3.75A, rated power 120W, typical efficiency 90%.
DDRH-120 series is a 250 ~ 1500Vdc high reliable ultra-high input DIN rail type DC-DC converter which can supply stable working voltage for the load. It is suitable to be mounted on TS-35/7.5 or 15 rails. Main features are as following: easy to install DIN rail type, narrow width(63mm) in slim design, -40~+80° C wide range operating temperature, 4KVac high isolation voltage, operation at 5000m altitude, high efficiency, low ripple & noise, complete protections and so on. DDRH-120 is compliant with UL1741 and BS EN/EN61000-6-2 standard regarding immunity for industrial environments. It is suitable for industrial automation, surveillance, telecommunication and can be widely deployed in the applications of new energy generation such as solar power, and windmill power generation, for instances, photovoltaic power systems, high voltage inverting , DC bus centralized application, ESS, charging pile, railway and so forth.
Features
- 250~ 1500Vdc 6:1 ultra-wide input range
- Withstand 1700Vdc surge input for 10 seconds
- 63mm slim width
- 4KVac I/O high isolation(Reinforced isolation)
- Protections: Short circuit / Overload / Over voltage / Over temperature DC input under voltage / DC input reverse polarity
- Fanless design, cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- -40~+80°C ultra-wide operating temperature (>+50°C derating)
- Over voltage categoryⅡ
- Operating altitude up to 5000 meters
- DC OK relay contact
- DC output voltage adjustable(12~15V, 24~29V, 30~36V, 48~58V)
- Conformal coating
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 32V
- RATED CURRENT
- 3.75A
- CURRENT RANGE
- 0 ~ 3.75A
- RATED POWER
- 120W
- RIPPLE & NOISE (max.)Note.2
- 240mVp-p
- VOLTAGE ADJ. RANGE
- 30 ~ 36V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- EXTERNAL CAPACITANCE LOAD (Max.)
- 2000μF
INPUT
- VOLTAGE RANGENote.4
- 250 ~ 1500Vdc
- EFFICIENCY (Typ.) 300Vdc
- 90%
- EFFICIENCY (Typ.) 800Vdc
- 91%
- EFFICIENCY (Typ.) 1500Vdc
- 87%
- INRUSH CURRENT (max.)
- COLD START 300A /1500Vdc 200A/800Vdc 70A/250Vdc
- EXTERNAL INPUT FUSE
- 4A/1500VDC, required(Please refer to page 4 for more details)
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Hiccup mode when output voltage<55%, recovers automatically after condition is removed; Constant current limiting, recovers automatically after fault condition is removed within 55% ~ 100% rated output voltage
- OVER VOLTAGE
- 40 ~ 48V Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- Protection type : Hiccup mode, recovers automatically after fault condition is removed
- DC INPUT REVERSE POLARITY
- By internal Bridge Diode, no damage, recovers automatically after fault condition removed
- DC INPUT UNDER VOLTAGE LOCKOUT
- Under voltage protection range:200 ~ 230Vdc , Under voltage release range:230 ~ 245Vdc
FUNCTION
- DC OK SIGNAL
- Relay contact rating(max.) : 30V / 1A resistive
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +80℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
- OPERATING ALTITUDENote.5
- 5000m
- OVER VOLTAGE CATEGORY
- OVCⅡ2000m; According to EN62109-1
SAFETY & EMC
- SAFETY STANDARDS
- UL1741, CSA C22.2 No.107.1-16 , IEC62109-1, BS EN/EN62109-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG :3.75KVAC O/P-FG :2KVAC O/P-DC OK:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) Class A Radiated BS EN/EN55032(CISPR32) Class A - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility BS EN/EN61000-4-3 Level 3, 10V, criteria A EFT/Burest BS EN/EN61000-4-4 Level 3, 2KV, criteria A Surge BS EN/EN61000-4-5 Level 4, 2KV/Vin+ ~ Vin-, 4KV/Vin ~ FG, criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V, criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A, criteria A
OTHERS
- MTBF
- 257.2 Khrs min. MIL-HDBK-217F (25℃); 1596.3 Khrs min. Telcordia TR/SR-332 (Bellcore) (25℃)
- DIMENSION
- 63*125.2*115mm (W*H*D)
- PACKING
- 0.845Kg; 12pcs/12.6Kg/1.02CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 800Vdc input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Photovoltaic power generation
- Renewable energy system
- High voltage frequency conversion
- Industrial control system
- Semiconductor fabrication equipment
- Electro-mechanical apparatus
- DC bus centralized application
- Energy storage system(ESS)
- Charging pile
- Third rail
Downloads
Datasheet1
FAQ
Can the DDRH-120-32 supply power to 32V brushless DC motors or drives?
The DDRH-120-32 provides 32V at 3.75A (120W) and is suited for powering 32V BLDC motors, servo drives, or DC drives with loads within that current rating. Its DIN rail mount integrates directly into control cabinet builds.
Is the DDRH-120-32 suitable for use in railway or traction DC bus applications?
The DDRH-120-32 accepts 250–1500VDC input, which covers many high-voltage DC bus levels for 32V auxiliary loads. However, the datasheet lists no railway standards — its approvals are UL1741, CSA C22.2 No.107.1-16, IEC62109-1 and BS EN/EN62109-1 — so confirm suitability for railway use before specifying it.
Can I use the DDRH-120-32 to power 32V LED drivers or lighting in industrial enclosures?
The DDRH-120-32 can supply up to 3.75A at 32V from a high-voltage DC input, making it usable for driving 32V LED lighting systems or constant-voltage LED drivers rated within 120W. The output is also adjustable from 30V to 36V for fine-tuning.
What input voltages does the DDRH-120-32 accept?
The DDRH-120-32 accepts a 250–1500VDC input, with an under-voltage lockout at 200–230VDC (release at 230–245VDC). This suits applications drawing from high-voltage DC sources such as solar string outputs or battery banks; an external 4A/1500VDC fuse is required.
Can the DDRH-120-32 operate in cold outdoor environments?
Yes. The DDRH-120-32 has an operating temperature range of -40°C to +80°C (with derating at higher ambient temperatures per the derating curve), making it appropriate for outdoor enclosures, cold-climate installations, and industrial environments where temperature extremes are expected.
How does the DDRH-120-32 compare to the other DDRH-120 series models?
The DDRH-120 series offers four output voltages: DDRH-120-12 (100.8W, 12V, 8.4A), DDRH-120-24 (120W, 24V, 5A), DDRH-120-32 (120W, 32V, 3.75A), and DDRH-120-48 (120W, 48V, 2.5A). All use the same 63mm DIN rail housing and accept 250–1500VDC input.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.