Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well NTU-3200-148US True Sine Wave DC-AC Inverter 3200W 110V out 48V in with US Socket, with AC by-pass function
Overview
NTU-3200-148US is the model of this series: typical efficiency 91%.
NTU-3200 is a 3200W highly reliable off-grid true sine wave DC-AC power inverter with built-in UPS function. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 6400W peak power, adjustable AC output voltage and frequency, -25~+70℃ wide operating temperature range, complete protection features, and etc. Combined with batteries, the NTU-3200 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Features
- Built-in UPS function (AC by-pass)
- True sine wave output (THD<3%)
- High surge power up to 6400W
- Temperature controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- -25℃~+70℃ wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections :
- Input : Reverse polarity / DC. low alarm / DC low shutdown / Over voltage
- Output : Short circuit / Overload / Over temp.
- Battery over discharge protection (low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Remote controller
- (IRC1, IRC2, IRC3 accessory sold separately, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1 )
- Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold sperately)
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Specifications
AC OUTPUT
- RATED POWER(Continuous)
- 3000W
- OVER RATED POWER(3 Min.)
- 3500W
- PEAK POWER(10 Sec.)
- 4500W
- SURGE POWER(30 Cycles)
- 6000W
- AC VOLTAGE
- Factory setting set at 110VAC 100 / 110 / 115 / 120Vac selectable by DIP S.W
- FREQUENCY
- Factory setting set at 60±0.1Hz 50/60Hz selectable by DIP S.W
- WAVEFORMNote.1
- True sine wave (THD<3%)
- AC REGULATION
- ±3.0% at rated output voltage
- FRONT PANEL LED
- Please see page 5
DC INPUT
- DC VOLTAGE
- 48Vdc
- VOLTAGE RANGE (Typ.)
- 40 ~ 66Vdc
- DC CURRENT (Typ.)
- 75A
- NO LOAD DISSIPATION (SAVING MODE)(Typ.)Note.2
- Default disable, auto detect AC output load≦10W will be changed to saving mode <15W
- OFF MODE CURRENT DRAW
- ≦2mA
- EFFICIENCY (Typ.)Note.1
- 91%
- BATTERY TYPES
- Lead Acid or li-ion
PROTECTION
- FUSE (INTERNAL)
- 25A*6
- LOW ALARM
- 44±1Vdc
- LOW SHUTDOWN
- 40±1Vdc
- LOW RESTART
- 50±1Vdc
- HIGH ALARM
- 62±1Vdc
- HIGH SHUTDOWN
- 66±1Vdc
- HIGH RESTART
- 60±1Vdc
- BAT. POLARITY
- By internal fuse open
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to recover
- OUTPUT SHORT
- Protection type : Shut down o/p voltage, re-power on to recover
- OVER LOAD (Typ.)
- 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
- CIRCUIT BREAKER
- 30A
- TB TYPE
- UL458 (Only for "TB" type AC socket)
FUNCTION CONTROL
- REMOTE CONNECTOR
- Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Normal work ; Short : Remote off
- ACCESSORY
- Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
- RS-232 COMMUNICATION
- RS-232 ~ RJ11 Type connector (Please refer to page 4 for more details)
AC UPS MODE
- AC INPUT RANGE
- 100/110/115/120Vac±16%, recover±13%
- FREQUENCY RANGE
- 45 ~ 65Hz
- TRASFER TIME(Typ.)
- 10ms inverter AC by pass
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃(Refer to "Derating curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
- VIBRATION
- 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- CB IEC62368-1,Dekra Seal BS EN/ EN62368-1,UL458, E13,EAC TP TC 004,AS/NZS 62368.1 approved (Please refer to next page “AC output socket” table for more details )
- WITHSTAND VOLTAGE
- DC I/P - AC I/P:3.0KVAC DC I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
- EMC EMISSION
-
Parameter Standard Test Level Radiated FCC for 112,124,148 only(expect for Type-UN) Class A Radiated BS EN/ EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A Conducted FCC for 112,124,148 only(expect for Type-UN) Class A Conducted BS EN/ EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote.5
-
BS EN/ EN55024, BS EN/ EN55035
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line 2KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 1 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 319.3K hrs min. Telcordia TR/SR-332 (Bellcore) ; 30.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 420*270*98mm (L*W*H)
- PACKING
- 8.6Kg; 1pcs/ 10.4Kg/ 1.39CUFT
Test conditions and notes5
- 1.Efficiency, AC regulation and THD are tested by 2400W load, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
- 2.No load dissipation at non-saving mode(Typ.): 112/124/148 for 25W, 212/224/248 for 55W.
- 3.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
- 4.Internal pre-start circuit, the setup time is 8s.
- 5.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehiclc
- Yacht
- Off-grid solar power system
Downloads
Catalogues1
FAQ
What is the main use case for the Mean Well NTU-3200-148US?
This model is a 3000W true sine wave DC-AC inverter designed for applications that need 110V AC output from a 48V DC input source. It is suited to business and industrial environments where clean AC power and higher surge capacity are important.
Does the NTU-3200-148US provide true sine wave output?
Yes. The NTU-3200-148US provides true sine wave output with total harmonic distortion below 3%, which helps support sensitive AC loads that benefit from cleaner power. This is a key differentiator versus modified sine wave inverters.
Does this inverter include an AC by-pass or UPS-type function?
Yes. The NTU-3200-148US includes a built-in UPS function with AC by-pass capability. That makes it suitable for applications where continuity of AC output is an important purchasing consideration.
What input and output voltages does this model support?
This specific model is a 48V DC input inverter (40 ~ 66Vdc range) with 110V AC output as the factory setting. Its AC output voltage is selectable by DIP switch among 100/110/115/120VAC, with 50/60Hz frequency selection, according to the product specification.
What kind of surge and overload capability does the NTU-3200-148US have?
The inverter is rated for 3000W continuous power and supports surge power up to 6000W. The specification also states overload performance of 105 to 115% load for 180 seconds and 115 to 150% load for 10 seconds.
Is the NTU-3200-148US compatible with lead-acid and lithium-ion battery systems?
Yes. Mean Well lists this model as suitable for both lead-acid and lithium-ion batteries. It also includes low DC input voltage protection, with an alarm at 44V, shutdown at 40V and restart at 50V.
Can this inverter be used in demanding environmental conditions?
It is designed for wide-temperature operation, with the general specification listing a working range of -25°C to +70°C with derating at higher temperatures. The unit is fan-cooled and has over-temperature protection, which supports use in more demanding operating environments.
What protection and monitoring features are included?
The NTU-3200-148US includes output short circuit, overload, over temperature, and high DC input voltage protections, along with low DC input voltage shutdown. It also has front panel status indicators, built-in remote on/off control, and supports an optional remote controller and RS-232 communication cable.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NTU-3200 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.