Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well NTU-3200-124US True Sine Wave DC-AC Inverter 3200W 110V out 24V in with US Socket, with AC by-pass function
Overview
NTU-3200-124US is the model of this series: typical efficiency 90%.
NTU-3200 is a 3200W highly reliable off-grid true sine wave DC-AC power inverter with built-in UPS function. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 6400W peak power, adjustable AC output voltage and frequency, -25~+70℃ wide operating temperature range, complete protection features, and etc. Combined with batteries, the NTU-3200 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Features
- Built-in UPS function (AC by-pass)
- True sine wave output (THD<3%)
- High surge power up to 6400W
- Temperature controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- -25℃~+70℃ wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections :
- Input : Reverse polarity / DC. low alarm / DC low shutdown / Over voltage
- Output : Short circuit / Overload / Over temp.
- Battery over discharge protection (low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Remote controller
- (IRC1, IRC2, IRC3 accessory sold separately, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1 )
- Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold sperately)
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Specifications
AC OUTPUT
- RATED POWER(Continuous)
- 3000W
- OVER RATED POWER(3 Min.)
- 3500W
- PEAK POWER(10 Sec.)
- 4500W
- SURGE POWER(30 Cycles)
- 6000W
- AC VOLTAGE
- Factory setting set at 110VAC 100 / 110 / 115 / 120Vac selectable by DIP S.W
- FREQUENCY
- Factory setting set at 60±0.1Hz 50/60Hz selectable by DIP S.W
- WAVEFORMNote.1
- True sine wave (THD<3%)
- AC REGULATION
- ±3.0% at rated output voltage
- FRONT PANEL LED
- Please see page 5
DC INPUT
- DC VOLTAGE
- 24Vdc
- VOLTAGE RANGE (Typ.)
- 20 ~ 33Vdc
- DC CURRENT (Typ.)
- 150A
- NO LOAD DISSIPATION (SAVING MODE)(Typ.)Note.2
- Default disable, auto detect AC output load≦10W will be changed to saving mode <15W
- OFF MODE CURRENT DRAW
- ≦2mA
- EFFICIENCY (Typ.)Note.1
- 90%
- BATTERY TYPES
- Lead Acid or li-ion
PROTECTION
- FUSE (INTERNAL)
- 40A*6
- LOW ALARM
- 22±0.5Vdc
- LOW SHUTDOWN
- 20±0.5Vdc
- LOW RESTART
- 25±0.5Vdc
- HIGH ALARM
- 31±0.5Vdc
- HIGH SHUTDOWN
- 33±0.5Vdc
- HIGH RESTART
- 30±0.5Vdc
- BAT. POLARITY
- By internal fuse open
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to recover
- OUTPUT SHORT
- Protection type : Shut down o/p voltage, re-power on to recover
- OVER LOAD (Typ.)
- 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
- CIRCUIT BREAKER
- 30A
- TB TYPE
- UL458 (Only for "TB" type AC socket)
FUNCTION CONTROL
- REMOTE CONNECTOR
- Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Normal work ; Short : Remote off
- ACCESSORY
- Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
- RS-232 COMMUNICATION
- RS-232 ~ RJ11 Type connector (Please refer to page 4 for more details)
AC UPS MODE
- AC INPUT RANGE
- 100/110/115/120Vac±16%, recover±13%
- FREQUENCY RANGE
- 45 ~ 65Hz
- TRASFER TIME(Typ.)
- 10ms inverter AC by pass
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃(Refer to "Derating curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
- VIBRATION
- 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- CB IEC62368-1,Dekra Seal BS EN/ EN62368-1,UL458, E13,EAC TP TC 004,AS/NZS 62368.1 approved (Please refer to next page “AC output socket” table for more details )
- WITHSTAND VOLTAGE
- DC I/P - AC I/P:3.0KVAC DC I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
- EMC EMISSION
-
Parameter Standard Test Level Radiated FCC for 112,124,148 only(expect for Type-UN) Class A Radiated BS EN/ EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A Conducted FCC for 112,124,148 only(expect for Type-UN) Class A Conducted BS EN/ EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote.5
-
BS EN/ EN55024, BS EN/ EN55035
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line 2KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 1 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 319.3K hrs min. Telcordia TR/SR-332 (Bellcore) ; 30.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 420*270*98mm (L*W*H)
- PACKING
- 8.6Kg; 1pcs/ 10.4Kg/ 1.39CUFT
Test conditions and notes5
- 1.Efficiency, AC regulation and THD are tested by 2400W load, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
- 2.No load dissipation at non-saving mode(Typ.): 112/124/148 for 25W, 212/224/248 for 55W.
- 3.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
- 4.Internal pre-start circuit, the setup time is 8s.
- 5.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehiclc
- Yacht
- Off-grid solar power system
Downloads
Catalogues1
FAQ
What is the Mean Well NTU-3200-124US designed for?
The NTU-3200-124US is a 3000W true sine wave DC-AC inverter for applications that need 110V AC output from a 24V DC source. It is suited to mobile, backup power, industrial, and other B2B power-conversion uses where clean AC output and higher surge capacity matter.
What input and output does this inverter support?
This model is a 24V DC input inverter (20 ~ 33Vdc range) with 110V AC output as the factory setting in the US version. The AC output voltage is selectable via DIP switch among 100/110/115/120VAC, and the output frequency between 50Hz and 60Hz.
Does the NTU-3200-124US provide true sine wave output?
Yes. This model provides true sine wave output with total harmonic distortion listed at under 3%, which is important for loads that require cleaner AC power. That makes it a better fit than modified sine wave units for more sensitive equipment.
Does this inverter include an AC bypass or UPS-style function?
Yes. The NTU-3200-124US includes a built-in UPS function with AC by-pass capability, as stated on the spec sheet. That makes it relevant for applications that need continuity between incoming AC power and inverter-backed output.
How much surge and overload capacity does this model have?
The rated output power is 3000W, and the product lists surge power up to 6000W. The overload specification also states 105 to 115% load for 180 seconds and 115 to 150% load for 10 seconds.
Is the NTU-3200-124US compatible with different battery chemistries?
Yes. The product data states that it is suitable for both lead-acid and lithium-ion batteries. It also includes low DC input voltage protection, with an alarm at 22V, shutdown at 20V and restart at 25V.
Is this inverter suitable for demanding operating environments?
This model is built for tougher environments with a working temperature range of -25 to +70C (with derating per the derating curve) and fan cooling. It also includes front-panel status indicators and protection for output short circuit, overload, over temperature, and high DC input voltage.
What certifications and warranty come with this inverter?
The NTU-3200-124US is listed with approvals including CB IEC62368-1, BS EN/EN62368-1, EAC TP TC 004, and AS/NZS 62368.1, along with FCC Class A EMC emissions; UL458 applies to the TB socket version only. The spec sheet does not state a warranty period.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NTU-3200 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.