Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well NPP-1200-48 1209.6W 48V Battery Charge& Power Supply 2-in-1, Selectable via Jumper 18A
Overview
NPP-1200-48 is the 57.6V output model of this series: rated current 18A, rated power 1209.6W, typical efficiency 94%.
NPP- 120 0 is a miniaturized dual-purpose charger and power supply. In addition to being used as a three-stage charger for lead-acid batteries, it can also be used as a constant voltage output power supply to drive general load. The operating mode can be quickly switched by plugging or unplugging a connector on the front panel. Other features include: ultra-wide voltage output, adjustable voltage via VR on the panel (10.5~21V, 21~42V, 42~80V), adjustable charging current (50~100%), built-in intelligent fan with variable speed based on temperature to reduce noise and extend fan lifetime, -30~+70° C wide operating temperature, suitability for use in different environments, built-in remote ON/OFF control, compliance to IEC/EN/UL62368-1 and household EN60335-1/-2-29 dual safety, multiple built-in protections, and 3-year warranty. The NPP- 120 0 is truly an intelligent, safe, and reliable universal dual-purpose charger and power supply with outstanding cost performance.
Features
- Multi-function single unit battery charger or power supply operation modes selectable
- Output voltage and current adjustable via potentiometer
- 3-stage charging curve for charging mode
- -30~+70℃ wide operating temperature
- Multiple protections: Short circuit / Over load / Over voltage / Over temperature
- Thermal controlled DC fan for noise reduction
- Remote ON-OFF control
- Comply with 62368-1+60335-1/-2-29 dual certification
- Suitable for lead-acid (Pb) batteries
- Carry handle accessory available (Order NO.:Carry handle, sold separately)
- 3 years warranty
Specifications
BATTERY CHARGER MODE (Default) - OUTPUT
- BOOST CHARGE VOLTAGE(Vboost)(default)
- 57.6V
- FLOAT CHARGE VOLTAGE(Vfloat)(default)Note.3: Float charge voltage(Vfloat) adjustable via potentiomerter in battery charger mode.
- 55.2V
- VOLTAGE ADJUSTABLE RANGE
- 42 ~ 80V (By built-in potentionmeter)
- MAX. OUTPUT CURRENT(CC)
- 18A
- CURRENT ADJUSTABLE RANGENote.3
- 9 ~ 18A (By built-in potentionmeter)
- MAX. POWER
- 1209.6W
- RECOMMENDED BATTERY CAPACITY (AMP HOURS)Note.4: This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
- 60 ~ 210AH
BATTERY CHARGER MODE (Default) - PROTECTION
- SHORT CIRCUITNote.7: This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
- Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover
- OVER VOLTAGE
- 82 ~ 100V Protection type : Shut down and latch off o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down O/P voltage, recovers automatically after temperature goes down
BATTERY CHARGER MODE (Default) - FUNCTION
- CHARGING STAGE
- 3 stage only
- CHARGER OK SIGNAL
- The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ; Charger failure or protection status =L( -0.5 ~ +0.5V)
- BATTERY FULL SIGNAL
- The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V)
- REMOTE CONTROL
- Open : Charger stop charging Short : Charger normal work
- FAN ON/OFF CONTROL
- Depends on internal temperature
OUTPUT
- DC VOLTAGE
- 57.6V
- VOLTAGE ADJUSTABLE RANGE
- 42 ~ 80V (By built-in potentionmeter)
- CURRENT ADJUSTABLE RANGE
- 9 ~ 18A
- RATED CURRENT
- 18A
- RATED POWER
- 1209.6W
- RIPPLE & NOISE(max.)
- 480mVp-p
- VOLTAGE TOLERANCE
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1800ms, 60ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC at 75% load 10ms/230VAC at full load
INPUT
- VOLTAGE RANGENote.3
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC at full load
- EFFICIENCY (Typ.)In battery charger mode measured at 16.8V charge voltage(12V model), 33.6V charge voltage(24V model), 67.2V charge voltage(48V model).
- 94%
- AC CURRENT (Typ.)
- 12A/115VAC 6.5A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 50A at 230VAC
PROTECTION
- OVERLOAD
- 105 ~ 115% rated output power Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover
- SHORT CIRCUIT
- Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover
- OVER VOLTAGE
- 82 ~ 100V Protection type : Shut down and latch off o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- REMOTE CONTROL
- Open : Power OFF Short : Power ON
- DC OK
- The TTL signal out, DC OK = H(4.5 ~ 5.5V) ; Power supply failure or protection = L(-0.5 ~ +0.5V)
- FAN SPEED CONTROL
- Depends on internal temperature
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 50℃ )
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2, 3V/m EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line,Level 3, 2KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2, 3Vrms Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 625.1K hrs min. Telcordia SR-332 (Bellcore) ; 63.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 250*158*67mm (L*W*H)
- PACKING
- 1.93Kg; 4pcs/ 10Kg / 1.72CUFT
Test conditions and notes5
- 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
- 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 3. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 4. The PSU is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Radio system backup solution
- Electric scooter charger
- Camping car、Buses、Heavy duty truck、Specialty vehicles
- Surveillance system
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
Downloads
Catalogues1
FAQ
What is the Mean Well NPP-1200-48 designed for?
The NPP-1200-48 is a 2-in-1 unit that can operate as either a battery charger or a power supply, selectable by jumper. It is intended for applications that need high-output DC power and support for lead-acid battery charging in a single model.
What are the main output ratings of the NPP-1200-48?
This model is rated for 1200W class output, with a listed power rating of 1209.6W. It has a 57.6V output voltage and a rated output current of 18A.
Is the NPP-1200-48 suitable for battery charging as well as continuous DC output?
Yes. Mean Well specifies this model as a battery charger and power supply in one unit, with selectable operating modes. In charging mode, it uses a 3-stage charging curve and is stated to be suitable for lead-acid batteries.
How adjustable is the output on the NPP-1200-48?
The NPP-1200-48 has a wide adjustable output voltage range of 42 to 80V, set with the potentiometer on the panel (the 10.5 to 21V and 21 to 42V ranges belong to the 12V and 24V models). Output current is also adjustable from 50% to 100% (9 to 18A), which helps match the unit to different system requirements.
Can the NPP-1200-48 be used in demanding temperature conditions?
Yes. This model is specified for operation from -30°C to +70°C, with output derating at higher temperatures per the derating curve, which makes it suitable for challenging industrial and commercial environments. It also includes a thermal-controlled cooling fan to reduce noise when full cooling is not needed.
What protection and safety features does the NPP-1200-48 include?
The NPP-1200-48 includes built-in protection for short circuit, overload, over voltage, and over temperature conditions. It is also described as compliant with IEC/EN/UL62368-1 and EN60335-1/-2-29 related safety standards, with approvals including CB, UL, DEKRA, and EAC.
How does the NPP-1200-48 compare with a standard fixed-output power supply?
Compared with a basic fixed-output supply, the NPP-1200-48 stands out by combining charger and power supply functions in one model. It also offers adjustable voltage and current, lead-acid charging support, and a wide -30°C to +70°C operating temperature range.
What warranty is offered with the NPP-1200-48?
Mean Well lists this model with a 3-year warranty. That can be an important advantage for buyers specifying power equipment for long-service commercial or industrial use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NPP-1200 Models
2 other models| Model | Power | Battery Type | Battery Voltage | Charging Current | |
|---|---|---|---|---|---|
| Mean Well NPP-1200-24 1209.6W 24V Battery Charge& Power Supply 2-in-1, Selectable via Jumper 36A | 1209.6W | Lithium and Lead Acid Battery | — | — | View |
| Mean Well NPP-1200-12 1176W 12V Battery Charge& Power Supply 2-in-1, Selectable via Jumper 70A | 1176W | Lithium and Lead Acid Battery | — | — | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.