Overview
ENP-360-12 is the 13.8V output model of this series: rated current 26A, typical efficiency 91%.
ENP-360 series is a 360W desktop type power supply working perfectly for communication related applications. Observing the standard 7" width size in the land mobile radio field, it provides the most frequently used voltage in the communication field. With the rugged mechanical design along with the high efficiency circuitry, it operates for the ambient temperature range -30℃~+70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- Energy efficiency Level Ⅵ
- No load power consumption <0.5W
- Comply with EISA 2007/DoE, NRCan and EU ErP
- 125% peak load capability
- Fanless design, cooling by free air convection
- Protection: Short circuit / Overload / Over voltage / Over temperature
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 13.8V
- RATED CURRENT
- 26A
- CURRENT RATED
- 0 ~ 26A
- CURRENT PEAKNote.2
- 32.6A
- WATTAGE RATED
- 359W
- WATTAGE PEAKNote.2
- 450W
- RIPPLE & NOISE (max.)Note.3
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 11.5 ~ 15V
- VOLTAGE TOLERANCENote.4
- ±1.0%
- LINE REGULATIONNote.5
- ±0.5%
- LOAD REGULATIONNote.6
- ±2.0%
- SETUP, RISE TIMENote.7
- 1000ms, 100ms at full load
- HOLD UP TIME (Typ.)
- 20ms at full load
INPUT
- VOLTAGE RANGENote.8
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC at full load
- EFFICIENCY (Typ.)
- 91%
- AC CURRENT (Typ.)
- 3.8A/115VAC 1.9A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 60A at 230VAC
- LEAKAGE CURRENT
- <3.5mA / 240VAC
- NO LOAD POWER CONSUMPTION
- <0.5W
PROTECTION
- SHORT CIRCUIT
- Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVERLOAD
- Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with auto-recovery after the peak load condition is removed Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
- OVER VOLTAGE
- 15.5 ~ 18.2V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down O/P voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1, UL62368-1, EAC TP TC 004, J62368-1(2020)(Only for 12V,24V) approved; Meet BS EN/ EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B Radiated BS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B Harmonic Current BS EN/EN61000-3-2 Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote 9
-
BS EN/EN55024; J55032(H29) (Only for 12V,24V)
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2, 3V/m EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2, 3Vrms Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 1199.8K hrs min. Telcordia SR-332 (Bellcore) ; 147.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 192*178*45.5mm (L*W*H)
- PACKING
- 1.5Kg; 10pcs/16Kg /1.38CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Peak current or peak power up to 3 seconds is provided.
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. Line regulation is measured from low line to high line at rated load.
- 6. Load regulation is measured from 0% to 100% rated load.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- 8. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Land mobile radio system
- Surveillance system
- TV antenna facility
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
What output does the Mean Well ENP-360-12 provide?
The ENP-360-12 is a 360W-class desktop power supply (359W rated) with a 13.8V DC output and 26A rated current. This makes it suitable for applications that need a regulated 13.8V supply at relatively high current from a compact external unit.
Is the ENP-360-12 designed for energy-efficient operation?
Yes. This model is a Level VI desktop power supply with a typical efficiency of 91% and no-load power consumption below 0.5W, as listed in the product data.
Can the ENP-360-12 handle temporary peak demand above its rated output?
Yes. Mean Well specifies a peak output of 450W (32.6A) for up to 3 seconds, and the overload protection section states it can normally operate at 110% to 125% of rated output power for more than 3 seconds. After that, it switches to constant-current limiting and auto-recovers once the overload condition is removed.
What operating temperature range is supported?
The specified working temperature range is -30°C to +70°C. Buyers should still confirm that the surrounding enclosure and overall system conditions stay within the product's published operating limits.
What protection and compliance features are included on the ENP-360-12?
This model includes short circuit, overload, over-voltage, and over-temperature protection. It is also listed with IEC62368-1, UL62368-1, J62368-1(2020) approval for the 12V version, and EMC compliance including EN55032 Class B and related EN61000 standards.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.