Overview
ENP-120-48 is the 55.2V output model of this series: rated current 2.2A, typical efficiency 91.5%.
ENP-120 series is a 120W desktop type power supply working perfectly for communication related applications. Observing the standard 7" width size in the land mobile radio field, it provides the most frequently used voltage in the communication field. With the rugged mechanical design along with the high efficiency circuitry, it operates for the ambient temperature range -30℃~+70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- Energy efficiency Level Ⅵ
- No load power consumption <0.15W
- Comply with EISA 2007/DoE, NRCan and EU ErP
- 125% peak load capability
- Fanless design, cooling by free air convection
- Protection: Short circuit / Overload / Over voltage / Over temperature
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 55.2V
- RATED CURRENT
- 2.2A
- CURRENT RATED
- 0 ~ 2.2A
- CURRENT PEAKNote.2
- 2.75A
- WATTAGE RATED
- 121W
- WATTAGE PEAKNote.2
- 151.8W
- RIPPLE & NOISE (max.)Note.3
- 350mVp-p
- VOLTAGE ADJ. RANGE
- 47.5 ~ 58.8V
- VOLTAGE TOLERANCENote.4
- ±1.0%
- LINE REGULATIONNote.5
- ±0.5%
- LOAD REGULATIONNote.6
- ±0.5%
- SETUP, RISE TIMENote.7
- 1000ms, 100ms at full load
- HOLD UP TIME (Typ.)
- 20ms at full load
INPUT
- VOLTAGE RANGENote.8
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC at full load
- EFFICIENCY (Typ.)
- 91.5%
- AC CURRENT (Typ.)
- 1.25A/115VAC 0.63A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 65A at 230VAC
- LEAKAGE CURRENT
- <3.5mA / 240VAC
- NO LOAD POWER CONSUMPTION
- <0.15W
PROTECTION
- SHORT CIRCUIT
- Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVERLOAD
- Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with auto-recovery after the peak load condition is removed Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
- OVER VOLTAGE
- 62.1 ~ 72.9V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down O/P voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1, UL62368-1, EAC TP TC 004 approved; Meet BS EN/ EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B Radiated BS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B Harmonic Current BS EN/EN61000-3-2 Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote 9
-
BS EN/EN55024
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2, 3V/m EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2, 3Vrms Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 1997.9K hrs min. Telcordia SR-332 (Bellcore) ; 257.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 192*178*45.5mm (L*W*H)
- PACKING
- 0.98Kg; 10pcs/10.8Kg /1.38CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Peak current or peak power up to 3 seconds is provided.
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. Line regulation is measured from low line to high line at rated load.
- 6. Load regulation is measured from 0% to 100% rated load.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- 8. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Land mobile radio system
- Surveillance system
- TV antenna facility
Downloads
Certificates8
Test reports1
Catalogues1
FAQ
What output does the Mean Well ENP-120-48 provide?
The ENP-120-48 is rated for 121W output at 55.2V DC and 2.2A. That makes it suitable for equipment or battery-charging applications designed for a 55.2V supply within that current range.
Is the ENP-120-48 a desktop-style power supply?
Yes. This model is a desktop-type unit in Mean Well's ENP-120 series, with a compact enclosure measuring 192 x 178 x 45.5 mm. It fits applications where a self-contained external power supply is preferred.
Can this model operate in demanding temperature conditions?
Yes. The ENP-120-48 has a specified operating temperature range of -30°C to +70°C. Output derating applies at higher ambient temperatures, so check the derating curve on the datasheet.
What protection features are included in the ENP-120-48?
This model includes short circuit, overload, over-voltage, and over-temperature protection. Its overload protection is specified at 110% to 125% with constant current limiting and auto-recovery.
Is the ENP-120-48 designed for energy-efficient operation?
Yes. The ENP-120-48 meets Energy Efficiency Level VI and has no-load power consumption below 0.15W. Its typical efficiency is 91.5%.
What input range and compliance standards does this power supply support?
The ENP-120-48 accepts a universal AC input range of 90 to 264VAC, and it also supports 127 to 370VDC input. It is certified to IEC62368-1 and UL62368-1 safety standards and meets EMC standards including EN55032 Class B.
What kinds of applications is the ENP-120-48 best suited for?
This model is suited to applications that need a regulated 55.2V DC desktop power source up to 121W, especially where energy efficiency matters. Its active PFC and 125% peak load capability make it a strong fit for commercial and industrial use cases that require a dependable external supply.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.