XLG-150-H-DA2 is the model of this series: rated current 2800mA, rated power 150W, typical efficiency 92%.
XLG-150-DA2 series is a 150W LED AC/DC driver featuring the constant power mode with DALI-2 dimming function. XLG-150-DA2 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 4170mA. Thanks to the high efficiency up to 93%, with the fanless design, the entire series is able to operate for -40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-150-DA2 series comply with the latest version of IEC61347/GB/T19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of user and luminaire system during installation.
Features
- Wide input range 100~305V AC( Class I)
- Full power output at 70~100% Constant power mode operation
- Metal case with IP67, suitable for outdoor application
- Surge protection with 6KV/4KV
- DALI-2 Dimming with minimum level 8%
- 12V/250mA Auxiliary power available(optional)
- India (EESL) version with Input Over Voltage Protection can survive input voltage stress of 440Vac for 48 hours
- Protection functions: SCP/OTP
- Life time >50,000 hrs. and 5 years warranty
Specifications
OUTPUT
- RATED CURRENT
- 2800mA
- RATED POWER
- 150W
- CONSTANT CURRENT REGIONNote.2
- 27 ~ 56V
- FULL POWER CURRENT RANGE
- 2680~4170mA
- OPEN CIRCUIT VOLTAGE (max.)
- 65V
- CURRENT ADJ. RANGE
- 1400~4170mA
- CURRENT RIPPLE
- 4.0%(@ full load)
- CURRENT TOLERANCE
- ±5%
- AUXILIARY DC OUTPUT
- 12V@250mA tolerance ±10%, ripple 200mVp-p (only for DA2-A-type)
- SET UP TIME
- 500ms/230VAC, 1200ms/115VAC
INPUT
- VOLTAGE RANGENote.4
- 100 ~ 305VAC 142VDC ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load (Please refer to "Power Factor Characteristic" section)
- TOTAL HARMONIC DISTORTION
- THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
- EFFICIENCY (Typ.)Note.14
- 92%
- AC CURRENT (Typ.)
- 1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 60A(twidth=500μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 4 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTION
- Standby power consumption <0.5W (Dimming OFF, Only for standard version DA2-type)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
- INPUT OVER VOLTAGENote.7
- 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) Can survive input voltage stress of 440Vac for 48 hours
- OVER TEMPERATURE
- Stage 1: Derating to 75% loading; stage 2: Derating to 50% loading. recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase=+90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.06%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC Input: 176-280Vdc) independent ,BS EN/EN62384; GB/T19510.1,GB/T19510.213; EAC TP TC 004; IS 15885(Part2/Sec13)(for XLG-150I-DA2 only); IP67 approved
- DALI STANDARDS
- Comply with IEC62386-101,102,207,251,Device type 6(DT6)
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 ,GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 -----; BS EN/EN61547 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 4KV/Line-Line 6KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 2316.2Khrs min. Telcordia SR-332 (Bellcore) ; 213.3Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 180*63*35.5mm (L*W*H)
- PACKING
- 0.8Kg;16pcs/13.4Kg/0.67CUFT
Test conditions and notes17
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE".
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.Especially when the temperature inside driver is very high, it will lead to a longer set up time.
- 6. Based on IEC 62386-101/102 DALI power on timing and interruption regulations,the set up time needs to test with a DALI controller which can support for DALI power on function,otherwise the set up time will be longer than 500ms.
- 7. Input over voltage only for XLG-150 I series,and I series without UL/CSA certificate.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- 13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 14. The efficiency will drop 1% based on auxiliary power version with full load 3W condition.
- 15. H/M type:RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations; L type:RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1
- 16. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- 17. This series need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- Street lighting
- Floodlight Lighting
- Stage lighting
- Fishing lighting
- Horticulture lighting
- Bay lighting
- Type HL for use in class I, Division 2
Downloads
Datasheet1
FAQ
Can the XLG-150-H-DA2 power LED downlights in a large commercial space with a DALI2 building management system?
Yes. At 150W and 2800mA with full DALI2 dimming support and a minimum dimming level of 8%, the XLG-150-H-DA2 is suitable for driving LED downlight arrays integrated into DALI2-based building automation systems. Its IP67 rating also accommodates damp ceiling or plenum installations.
Is the XLG-150-H-DA2 suitable for powering high-wattage outdoor LED flood or area lighting?
Yes. The driver is IP67 waterproof and rated for -40°C to +90°C operation, making it appropriate for outdoor flood or area lighting fixtures. It delivers 150W at 2800mA constant current within a 27–56V output range.
Can I use the XLG-150-H-DA2 for theatrical or architectural LED lighting where fine dimming control is needed?
Yes. The DALI2 interface provides smooth dimming down to 8% minimum, and the output current is adjustable from 1400mA to 4170mA, giving flexibility for architectural or theatrical LED installations requiring precise light level control.
What LED string voltage range does the XLG-150-H-DA2 support, and how does that determine LED count?
The constant current operating region is 27–56V. The number of LEDs you can place in series depends on each LED's individual forward voltage — the total string voltage must fall within that 27–56V window.
How does the XLG-150-H-DA2 compare to the XLG-100-H-DA2 and XLG-200-H-DA2?
The XLG-100-H-DA2 is rated 100W at 2100mA, the XLG-150-H-DA2 at 150W at 2800mA, and the XLG-200-H-DA2 at 200W at 3500mA. All three share the same H-series constant current region and DALI2 interface; the differences are wattage and maximum output current.
Can the XLG-150-H-DA2 be installed in a wet or wash-down environment?
The XLG-150-H-DA2 carries an IP67 rating, meaning it is protected against dust ingress and temporary immersion in water up to 1 meter. It is suitable for damp or splash-prone installations but should not be permanently submerged.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.