Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
XLG-150-24-A is the 24V output model of this series: rated power 150W, typical efficiency 93%.
XLG-150 series is a 150W LED AC/DC driver featuring the constant power mode.XLG-150 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 12500mA. Thanks to the high efficiency up to 93%, with the fanless design, the entire series is able to operate for -40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-150 series comply with the latest version of IEC61347/GB/T19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.
Features
- Wide input range 100~305V AC( Class I)
- Full power output at 70~100% Constant power mode operation
- Metal case with IP67, suitable for outdoor application
- Surge protection with 6KV/4KV (10KV/6KV optional)
- 3 in 1 dimming function (Dim to off and Isolation design)
- India (EESL) version with Input Over Voltage Protection can survive input voltage stress of 440Vac for 48 hours
- Protection functions: OVP/SCP/OCP/OTP
- Compliance to EN60335-1 household application
- Life time >50,000 hrs. and 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- CONSTANT CURRENT REGIONNote.2
- 16.8~ 24V
- RATED CURRENT (Default)
- 6.25A
- RATED POWER
- 150W
- RIPPLE & NOISE (max.)Note.3
- 240mVp-p
- CURRENT ADJ. RANGE
- Adjustable for A-Type only (via the built-in potentiometer)
- CURRENT ADJ. RANGE
- 3.2~ 6.25A
- VOLTAGE TOLERANCENote.4
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1%
- SETUP, RISE TIMENote.6
- 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
- HOLD UP TIME (Typ.)
- 10ms/ 230VAC 10ms/ 115VAC
INPUT
- VOLTAGE RANGENote.5
- 100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
- TOTAL HARMONIC DISTORTION
- THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT
- 1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 50A(twidth=500μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- NO LOAD POWER CONSUMPTION
- No load power consumption <0.5W(for standard version)
PROTECTION
- OVER CURRENT
- 110 ~ 160% for CV type, 95~108% for other type; CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
- SHORT CIRCUIT
- CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
- OVER VOLTAGE
- 27 ~ 34V; Shut down output voltage, re-power on to recover
- INPUT OVER VOLTAGE
- 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) Can survive input voltage stress of 440Vac for 48 hours(Input over voltage only for XLG-150I series)
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase=+90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.06%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL8750(type”HL”), UL879,CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, EN 60335-1 compliant to EN 60335-2-89 Annex BB, EN 60335-2-24 Annex CC;GB/T19510.1,GB/T19510.213;EAC TP TC 004; J61347-1(H29), J61347-2-13 (H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-150I type only);NOM-058-SCFI-2017(except for Blank type);IP67 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 ,GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61547
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option) Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 2269.5K hrs min. Telcordia SR-332 (Bellcore) ; 213.3Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 180*63*35.5mm (L*W*H)
- PACKING
- 0.8Kg;16pcs/13.4Kg/0.69CUFT
Test conditions and notes16
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE". (Except for CV-type)
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. Only CE/ENEC/CB is available for CV-type. XLG-150I series without UL/CSA certificate.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- 13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- 15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.
- 16. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- Skyscraper lighting
- Street lighting
- Floodlight Lighting
- Stagelight
- Horticulture lighting
- Bay lighting
- DMX power supply
- Type HL for use in class I, Division 2
- Household devices
- Retail and refrigerated display
Downloads
FAQ
Can I use the XLG-150-24-A for 24V LED strip lighting in coves or linear runs?
Yes, this driver is intended for 24V LED lighting loads up to 150W with 6.25A available output current. It suits 24V strip lighting projects when the combined strip load does not exceed 150W.
Is this suitable for 24V sign lighting or illuminated cabinets?
It can be used for 24V signage and cabinet lighting as long as the total load stays within 150W at 24V. The IP67 Waterproof rating also makes it appropriate for signs installed in exposed conditions.
Can the XLG-150-24-A power outdoor 24V architectural accent lighting?
Yes, for compatible 24V LED lighting loads up to 150W, this model is suitable for outdoor accent applications. Its IP67 Waterproof rating and -40°C to +90°C operating range support demanding environments.
How do I estimate LED strip length with this 24V 150W driver?
The maximum available strip power is 150W at 24V. To estimate run length, divide 150W by your strip's rated watts per meter, and check your strip rated power per meter before final selection.
Is the XLG-150-24-A okay for wet locations or exposed outdoor enclosures?
Yes, the IP67 Waterproof rating means it is designed for applications where water and dust protection matter. Its metal case and operating temperature range of -40°C to +90°C add suitability for tough outdoor conditions.
How does XLG-150-24-A compare with the other 150W XLG voltage options?
XLG-150-24-A and XLG-150-24-AB are both 150W, 24V, 6.25A models. The 12V versions are XLG-150-12-A and XLG-150-12-AB at 150W, 12V, 12.5A, while higher-voltage 150W siblings include XLG-150-L-A at 700mA and XLG-150-M-A at 1400mA.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.