Mean Well XLC-60-H-MAS LED Driver 60W 1400mA 9~54V Constant Power, Current Setting by Dip Switch, Matter Wireless Dimming with Strain Relief
Notify me when it's back in stock
Your order will be processed within 24 hours
Overview
XLC-60-H-MAS is the model of this series: rated power 60W, typical efficiency 90%.
XLC-60-MA series is a 60W with constant power and constant voltage output LED driver . It can operate from 100~305V AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch. Thanks to high efficiency up to 90%, it is able to operate for -25℃ ~90℃ case temperature under free air convection. XLC-60-MA series is designed based on latest safety regulations with matter wireless dimming .It provides more flexibility for LED Lighting application.
Features
- Constant power mode output with multiple stage selectable by DIP switch (H-type)
- Constant voltage mode output(12/24/48V)
- Plastic housing with class Ⅱ and PFC design
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) application
- Minimum dimming level 0.1% (12/24/48V)
- Minimum dimming level 0.5% (H-type)
- Matter over thread, Matter 1.3 specification
- 5 years warranty
Specifications
OUTPUT
- OPEN CIRCUIT VOLTAGENote.2
- 60V
- DEFAULT CURRENT
- 1400mA
- CURRENT ADJ. RANGE (BY DIP SWITCH)
- 0.9~1.7A
- CONSTANT CURRENT REGION
- 9~54V
- RATED POWERNote.2 (12/24/48V), Note.4 (H)
- 60W
- CURRENT RIPPLENote.5
- <4%
- CURRENT TOLERANCE
- ±5%
- DIMMING RANGE
- 0~100%
- SETUP, RISE TIMENote.3 (12/24/48V), Note.6 (H)
- 2500ms,100ms/230VAC ,2500ms,100ms/115VAC
INPUT
- VOLTAGE RANGE
- 100~305VAC 155~400VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≥0.95/115VAC, PF≥0.95/230VAC, PF≥0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY(Typ.)Note.7 (H)
- 90%
- AC CURRENT
- 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC
- INRUSH CURRENT
- COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTIONNote.4 (12/24/48V), Note.9 (H)
- Standby power consumption<0.5W (Dimming off)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=90℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176-280VDC); BS EN/EN62384 , GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
- WITHSTAND VOLTAGE
- I/P-O/P: 3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥60% Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61547
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods
OTHERS
- MATTER STANDARD
- Matter 1.3 Specification
- FLICKERNote.7 (12/24/48V), Note.10 (H)
- PstLM ≤ 1, SVM ≤ 0.4
- MTBF
- 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 176*45*32mm , 136*45*32mm (L*W*H)
- PACKING
- 0.28Kg; 40pcs/12Kg/0.48CUFT(for Blank type); 0.30Kg; 40pcs/13Kg/0.63CUFT(for S-type);
Test conditions and notes14
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Output hiccups under no-load condition.
- 3. Please refer to “DRIVER METHODS OF LED MODULE”.
- 4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 5. Current ripple is measured 50%~100% of maximum voltage under rated power delivery.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. Efficiency is measured at 1050mA/54V output set by DIP switch.
- 8. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 9. Standby power consumption is measured at 230VAC.
- 10. Flicker is measured at full load with the light source provided by MEAN WELL.
- 11. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 12. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 13. This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about75℃ or less.
- 14. For more information, please contact with MEAN WELL sales.
Technical drawings
Typical applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- Matter wireless Lighting
FAQ
Can the XLC-60-H-MAS be used to dim LED downlights wirelessly through a Matter smart home system?
Yes, the XLC-60-H-MAS supports Matter 1.3 wireless dimming, enabling integration with Matter-compatible hubs and voice assistants for wireless control of LED downlight loads. The driver outputs 60W at 1400mA default current with a 9–54V constant current region.
Is the XLC-60-H-MAS appropriate for new-construction LED lighting where cables need a strain-relief termination?
The XLC-60-H-MAS includes an integrated strain-relief fitting, making it suited for new-construction or retrofit installations where cable strain management at the driver housing is required by local codes or installation practice. It provides 60W Matter-dimmable constant current output.
Can I use the XLC-60-H-MAS in a commercial space that requires flicker-free, dimmable LED lighting?
The XLC-60-H-MAS is rated flicker-free (PstLM ≤ 1, SVM ≤ 0.4) and supports Matter 1.3 wireless dimming with a current adjustment range of 0.9–1.7A, making it applicable for commercial environments with flicker-sensitivity requirements such as photography studios or healthcare facilities.
How many LEDs can the XLC-60-H-MAS drive in a series configuration?
The driver's constant current output covers 9–54V; the number of series LEDs is determined by each LED's forward voltage and is not a fixed number. Select a series string whose total forward voltage stays within the 9–54V CC range at the desired operating current.
What is the operating temperature range of the XLC-60-H-MAS, and can it handle high-temperature luminaire cavities?
The XLC-60-H-MAS is rated for -25°C to +90°C operation, accommodating high-temperature luminaire cavities or installation environments. No IP rating is specified, so it requires a suitable enclosure in wet or outdoor locations.
What is the difference between the XLC-60-H-MA and the XLC-60-H-MAS?
Both models are 60W, 1400mA constant current drivers with Matter 1.3 wireless dimming and a 9–54V CC range. The XLC-60-H-MAS includes a strain-relief fitting and is 176mm long, while the XLC-60-H-MA lacks strain-relief and is 136mm long.