Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
XLC-60-H is the model of this series: rated power 60W, typical efficiency 90%.
XLC-60 Series is a 60W with constant power and constant voltage output LED driver . It can operate from 100 ~ 305VAC and output current ranging between 900 mA to 1700 mA selectable by DIP switch or NFC setting. Thanks to high efficiency up to 90%, it is able to operate for -25℃ ~90℃ case temperature under free air convection. XLC-60 is designed based on latest safety regulations with 3 in 1 and DALI-2 dimming. XLC-60 can also be adjusted for brightness with a push button as a simple way dimming, so it provides more flexibility for LED Lighting application.
Features
- Constant power mode output with multiple stage selectable by DIP switch or NFC setting (H-type)
- Constant voltage mode output(12/24/48V)
- Plastic housing with class Ⅱ and PFC design
- Meet UL8750 Class 2 / Class P power unit
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) application
- Minimum dimming level 0.1% (DALI-2 DT6)
- Dimming functions: 3 in 1 dimming (Dim-to-off DALI-2 + Push dimming
- 5 years warranty
Specifications
OUTPUT
- OPEN CIRCUIT VOLTAGENote14
- 60V
- DEFAULT CURRENT
- 1400mA
- CURRENT ADJ. RANGE (BY DIP SWITCH OR NFC)
- 0.9~1.7A
- CONSTANT CURRENT REGION
- 9~54V
- RATED POWER
- 60W
- CURRENT RIPPLENote4
- <4%
- CURRENT TOLERANCE
- ±5%
- DIMMING RANGE
- 0~100%
- SETUP, RISE TIMENote12 (H-type)
- 800ms,100ms/230VAC ,1000ms,100ms/115VAC
INPUT
- VOLTAGE RANGE
- 100 ~ 305VAC 155 ~400VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≥0.95/115VAC, PF≥0.95/230VAC, PF≥0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY(Typ.)Note11 (H-type: measured at 1050mA/54V output set by DIP switch)
- 90%
- AC CURRENT
- 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC
- INRUSH CURRENT
- COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTIONNote5
- Standby power consumption<0.5W (Dimming OFF, only for standard version B/DA2-type)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- DA2 type: Stage 1: Derating to 75% loading; stage2: Derating to 50% loading; Recovers automatically after fault condition is removed. Blank & B type: Derating to lowest output level, Recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=90℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP.,HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY&EMC
- SAFETY STANDARDS
- UL8750(Class P), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 , BIS IS15885(Part2/Sec13)(NOTE 13), GB/T19510.1, GB/T19510.213, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
- DALI STANDARDS
- Comply with IEC62386-101, 102, 207
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥60% Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61547
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods
OTHERS
- FLICKERNote.9
- PstLM ≤ 1, SVM ≤ 0.4
- MTBF
- 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 176*45*32mm , 136*45*32mm (L*W*H)
- PACKING
- 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for XLC-60 Series); 0.39Kg; 40pcs/16.6Kg/0.61CUFT(for XLC-60-S Series);
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 4. Current ripple is measured 50%~100% of maximum voltage under rated power delivery.
- 5. Standby power consumption is measured at 230VAC.
- 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 8. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. Flicker is measured at full load with the light source provided by MEAN WELL.
- 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 11. This series meets the typical life expectancy of 50000 hours of operation when Tcase,particularly tc point(or TMP,per DLC), is about 75℃ or less.
- 12. For more information, please contact with MEAN WELL sales.
- 13. Products sourced from the China regions and some models sourced from India may not have the BIS logo,please refer to BIS certificate for details and contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- DALI digital Lighting
Downloads
Datasheet1
FAQ
Can I use the XLC-60-H to drive LED downlights in a commercial ceiling fixture?
Yes. The XLC-60-H delivers 60W at a constant current of 1400mA across a CC voltage range of 9–54V, making it well suited for LED downlight modules that operate within that voltage window. Its flicker-free output (PstLM ≤ 1, SVM ≤ 0.4) is appropriate for occupied commercial spaces.
Is the XLC-60-H suitable for powering LED signage modules?
Yes, the XLC-60-H can drive LED signage modules whose forward voltage requirements fall within the 9–54V CC output range. The driver operates at up to 60W, so the total load of the sign modules must stay within that power limit. Note that the unit is IP20 (built-in type) and requires a suitable enclosure for outdoor signage.
Can I use the XLC-60-H in a small LED array application?
Yes. The driver maintains a constant current output adjustable from 0.9A to 1.7A via the dip switch or NFC, which allows tuning for different LED array configurations. The number of LEDs that can be driven depends on each LED's forward voltage within the 9–54V operating range.
Is the XLC-60-H rated for indoor built-in use only, or can it be used in outdoor enclosures?
The XLC-60-H is designed for built-in use inside a luminaire or enclosure. It does not carry an IP rating for direct outdoor exposure, so it should be installed inside a suitable housing if used in outdoor environments.
What is the operating temperature range of the XLC-60-H?
The XLC-60-H operates from -25°C to +90°C case temperature, accommodating a wide range of installation environments from cold storage to high-ambient industrial spaces.
How does the XLC-60-H current output relate to the number of LEDs I can drive?
The XLC-60-H provides a constant current output adjustable between 0.9A and 1.7A across a CC voltage range of 9–54V. The number of LEDs in the string depends on each LED's individual forward voltage; there is no fixed LED count.
How does the XLC-60-H differ from the XLC-25-H and XLC-40-H siblings in this series?
The XLC-60-H delivers 60W at 1400mA with a 9–54V CC range. Other models in the series vary in wattage and current; for example, the XLC-40-H delivers 40W at 1050mA. Choose based on the total wattage and current required by your LED load.
Payment & Security