Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well XLC-40-H-MAS LED Driver 40W 1050mA 9~54V Constant Power, Current Setting by Dip Switch, Matter Wireless Dimming with Strain Relief
Notify me when it's back in stock
Your order will be processed within 24 hours
Overview
XLC-40-H-MAS is the model of this series: rated power 40W, typical efficiency 88%.
XLC-40-MA series is a 40W with constant power output LED driver . It can operate from 100~305VAC and output current ranging between 600 mA to 1400 mA selectable by DIP switch . Thanks to high efficiency up to 88%, it is able to operate for -25℃~90℃ case temperature under free air convection. XLC-40-MA series is designed based on latest safety regulations with Matter wireless dimming.It provides more flexibility for LED Lighting application.
Features
- Constant power mode output with multiple stage selectable by DIP switch
- Plastic housing with class II and PFC design
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) function application
- Minimum dimming level 0.5%
- Matter over thread, Matter 1.3 specification
- 5 years warranty
Specifications
OUTPUT
- OPEN CIRCUIT VOLTAGENote.2
- 60V
- DEFAULT CURRENT
- 1050mA
- CURRENT ADJ.RANGE (BY DIP SWITCH)
- 0.6~1.4A
- CONSTANT CURRENT REGIONNote.3
- 9~54V
- RATED POWERNote.4
- 40W
- CURRENT RIPPLE
- <4%(@full load)
- CURRENT TOLERANCE
- ±5%
- DIMMING RANGE
- 0~100%
- SETUP, RISE TIMENote.5
- 2500ms, 100ms/230VAC, 2500ms, 100ms/115VAC
INPUT
- VOLTAGE RANGE
- 100 ~ 305VAC 141 ~ 400VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD<10%(@load≧50%/230VAC; @load≧75%/277VAC), THD<15%(@load≧50%/115VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY (Typ.)Note.6
- 88%
- AC CURRENT
- 0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 10A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTIONNote.7
- Standby power consumption<0.5W(Dimming off)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- Tcase=-25 ~ 90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=90℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations( DC input 176-280V DC); BS EN/EN62384, GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 ; CSA C22.2 No. 250.13-12 approved ; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13;
- WITHSTAND VOLTAGE
- I/P-O/P: 3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 -----; BS EN/EN61547 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods
OTHERS
- MATTER STANDARD
- Matter 1.3 Specification
- FLICKERNote.8
- PstLM ≤ 1, SVM ≤ 0.4
- MTBF
- 3935.2 K hrs min. Telcordia SR-332 (Bellcore); 342.9 Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 147*40*32mm,107*40*32mm (L*W*H)
- PACKING
- 193g; 60pcs/12.58Kg/0.58CUFT(for blank type); 210g; 50pcs/11.5Kg/0.57CUFT(for S-type)
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Output hiccups under no-load condition.
- 3. Please refer to “DRIVER METHODS OF LED MODULE”.
- 4. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 6. Efficiency is measured at 800mA/50V output set by dip-switch.
- 7. Standby power consumption is measured at 230VAC.
- 8. Flicker is measured at full load with LED modules.
- 9. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1
- 11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 12. The ambient temperature de-rating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 13. For more information, please contact with MEAN WELL sales.
Technical drawings
Typical applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- Matter wireless Lighting
Downloads
Datasheet1
FAQ
Can the XLC-40-H-MAS dim LED downlights wirelessly through a Matter smart home system?
Yes, the XLC-40-H-MAS supports Matter 1.3 wireless dimming and integrates with Matter-compatible controllers, apps, and voice assistants. It delivers 40W at 1050mA constant current and can power LED downlights in the 9–54V CC range, allowing scene-based or automated brightness control without a separate in-wall dimmer.
Is the XLC-40-H-MAS a good option for commercial LED downlight installations that require wireless control and cable strain relief?
The XLC-40-H-MAS is well suited to commercial installations where both Matter wireless dimming and mechanical cable security are needed. The built-in strain-relief fitting protects the output cable connection in applications where cables are routed through conduit or subject to tension, while Matter 1.3 enables integration with building or hospitality control systems.
Can the XLC-40-H-MAS power LED modules in architectural or cove lighting with automated scene control?
Yes, the XLC-40-H-MAS suits architectural cove lighting where scene automation is managed through a Matter hub. Its 40W, 1050mA output drives LED arrays in the 9–54V CC range, and the flicker-free design ensures consistent light quality during smooth dimming transitions triggered by schedules or occupancy sensors.
What is the difference between the XLC-40-H-MA and the XLC-40-H-MAS?
Both the XLC-40-H-MA and XLC-40-H-MAS deliver 40W at 1050mA with Matter 1.3 wireless dimming and identical CC voltage range, certifications, and current adjustment capability. The XLC-40-H-MAS adds a factory-fitted strain-relief cable fitting and has a longer 147.0mm body versus the XLC-40-H-MA's 107.0mm body. The strain-relief variant is preferable where output cables may experience mechanical stress.
What LED array voltage range is the XLC-40-H-MAS compatible with?
The XLC-40-H-MAS constant current output spans a CC voltage range of 9–54V, making it compatible with a broad variety of LED arrays and modules. The exact number of LEDs per string depends on the forward voltage of each LED — you should sum the Vf values of your specific LEDs to confirm they fall within this range.
Can the XLC-40-H-MAS be installed inside an enclosed luminaire in a warm ceiling space?
Yes, the XLC-40-H-MAS is designed for built-in installation inside a luminaire or enclosure. Its operating temperature range of -25°C to +90°C covers the elevated ambient conditions found in enclosed ceiling fixtures and recessed housings. It is Class II rated and does not require an earth connection.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.