Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
XLC-25-H-B is the model of this series: rated power 25W, typical efficiency 88%.
XLC-25 Series is a 25W with constant power and constant voltage output LED driver . It can operate from 100~305VAC and output current ranging between 300 mA to 1050 mA selectable by dip switch or NFC setting. Thanks to high efficiency up to 88%, it is able to operate for -25℃ ~85℃ case temperature under free air convection. XLC-25 is designed based on latest safety regulations with 3 in 1 and DALI-2 dimming. XLC-25 can also be adjusted for brightness with a push button as a simple way dimming, so it provides more flexibility for LED Lighting application.
Features
- Constant power mode output with multiple stage selectable by dip switch or NFC setting(H-type)
- Constant voltage mode output (12V/24V)
- Plastic housing with class II and PFC design
- Meet UL 8750 Class 2 / Class P power unit
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) application
- Minimum dimming level 0.1% (DALI-2 DT6)
- Dimming functions: 3 in 1 dimming (Dim-to-off)
- DALI-2 + Push dimming
- 5 years warranty
Specifications
OUTPUT
- OPEN CIRCUIT VOLTAGE
- 60V
- DEFAULT CURRENT
- 700mA
- CURRENT ADJ.RANGE (BY DIP SWITCH OR NFC)
- 0.3~1.05A
- CONSTANT CURRENT REGION
- 9~54V
- RATED POWER
- 25W
- CURRENT RIPPLE
- <4%
- CURRENT TOLERANCE
- ±5%
- DIMMING RANGE
- 0~100%
- SETUP, RISE TIME
- 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
INPUT
- VOLTAGE RANGE
- 100 ~ 305VAC 141 ~ 400VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD<10%(@load≧50%/230VAC; @load≧75%/277VAC), THD<15%(@load≧50%/115VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT
- 0.35A / 115VAC 0.18A / 230VAC 0.15A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 10A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 71 units (circuit breaker of type B) / 71 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTION
- Standby power consumption<0.5W(Dimming off)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- Blank & B type: De-rating to lowest output level. Recovers automatically after fault condition is removed. DA2 type: Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- Tcase=-25 ~ 85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=85℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384 independent, BIS IS15885(Part2/Sec13)(NOTE 14), GB/T19510.1, GB/T19510.213, EAC TP TC 004, UL8750(Class P); CSA C22.2 No. 250.13-12 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
- DALI STANDARDS
- Comply with IEC62386-101,102,207
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 -----; BS EN/EN61547 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods
OTHERS
- FLICKER
- PstLM ≤ 1, SVM ≤ 0.4
- MTBF
- 3949.8 K hrs min. Telcordia SR-332 (Bellcore) ; 338.5 Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 147*40*32mm,107*40*32mm (L*W*H)
- PACKING
- 141.6g; 60pcs/8.4Kg/0.58CUFT(for blank type); 160g; 50pcs/8.1Kg/0.57CUFT(for S-type)
Test conditions and notes14
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
- 4. Tolerance: includes set up tolerance, line regulation and load regulation.
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 6. Flicker is measured at full load with the light source provided by MEAN WELL.
- 7. To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature de-rating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- 11. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations.
- 12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- 13. For more information, please contact with MEAN WELL sales.
- 14. Products sourced from the China regions and some models sourced from India may not have the BIS logo,please refer to BIS certificate for details and contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- DALI digital Lighting
Downloads
::specification::
FAQ
Can the XLC-25-H-B drive LED downlights with dimming control from a building automation system?
Yes. The XLC-25-H-B supports 3-in-1 dimming (0–10V, PWM, and resistance), allowing it to interface with most commercial building automation and lighting control systems. It delivers 700mA constant current across a 9–54V output range for up to 25W.
Is the XLC-25-H-B suitable for dimmable LED signage modules?
Yes. The driver supports 3-in-1 dimming and its current is adjustable from 0.3A to 1.05A via dip switch, so it can be matched to signage LED modules with varying drive current requirements while maintaining dimming capability.
Can I use the XLC-25-H-B in a flicker-sensitive retail or museum lighting application?
Yes. The XLC-25-H-B is rated flicker-free, making it appropriate for retail display cases, museum accent lighting, and other environments where flicker could affect visual quality or occupant comfort.
Does the XLC-25-H-B work for tunable-white or multi-channel LED fixtures?
The XLC-25-H-B is a single-channel constant current driver outputting 700mA. It is not natively designed for multi-channel tunable-white control; a separate channel driver would be needed per LED string. However, it can dim a single string as part of a larger tunable-white system.
What dimming interfaces does the XLC-25-H-B accept?
The XLC-25-H-B accepts 3-in-1 dimming: 0–10V analog, PWM signal, and resistance-based dimming. All three interfaces share the same driver model, so the control method is selected by how the dimming input is wired.
Is the XLC-25-H-B rated for indoor built-in luminaire use?
Yes. The XLC-25-H-B is designed for built-in use within luminaire housings. Its operating temperature range of -25°C to +85°C (case temperature) accommodates the elevated ambient temperatures typical inside recessed or enclosed fixtures.
Payment & Security