Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLP-60-48 is the 48V output model of this series: rated current 1.3A, rated power 62.4W, typical efficiency 89%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Over current / Over voltage
- Built-in active PFC function
- Cooling by free air convection
- Class 2 power unit
- Output current level adjustable
- 100% full load burn-in test
- High reliability
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.5
- 36 ~ 48V
- RATED CURRENT
- 1.3A
- CURRENT RANGE
- 0 ~ 1.3A
- RATED POWER
- 62.4W
- RIPPLE & NOISE (max.)Note.2
- 4.8Vp-p
- CURRENT ADJ. RANGE
- 0.975 ~ 1.3A
- VOLTAGE TOLERANCENote.3
- ±10%
- LINE REGULATION
- ±3.0%
- LOAD REGULATION
- ±5.0%
- SETUP TIME
- 500ms / 230VAC 1200ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.9 at 75 ~ 100% load, 115VAC / 230VAC
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≥75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 0.8A/115VAC 0.4A/230VAC
- INRUSH CURRENT (max.)
- COLD START 35A(twidth=55μs measured at 50% Ipeak) at 230VAC
- MAX.No. of PSUs on 16A CIRCUIT BREAKER
- 32units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENTNote.5
- 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 57 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- GB/T19510.1,GB/T19510.213 ,UL8750, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V) , EAC TP TC 004 approved ; design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to GB/T 17743, GB17625.1, BS EN/EN55015, BS EN/EN61000-3-2 Class C(≧75% load); BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 5065.8K hrs min. Telcordia SR-332 (Bellcore) ; 583.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 101.6*50.8*29.6mm (L*W*H)
- PACKING
- 0.16Kg; 96pcs/16.4Kg/0.89CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 5. Please refer to "DRIVING METHODS OF LED MODULE".
- 6. Heat sink HS1,HS2 can not be shorted.
- 7. Heat sink HS1 must have safety isolation distance with system case.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 11. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 12. PLP-60-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products(including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps) .
Technical drawings
Typical applications
- Suitable for built-in applications of LED lighting
- 2 years warranty
Downloads
Datasheet1
FAQ
What is the output of the Mean Well PLP-60-48?
The PLP-60-48 is a single output LED driver rated for 48V DC output. It delivers up to 62.4W with a rated current of 1.3A.
Is the Mean Well PLP-60-48 dimmable?
The spec sheet does not list any dimming function for this model. It only specifies a current adjustment range of 0.975 to 1.3A, so plan for a fixed-output LED driver rather than integrated dimming control.
What kinds of applications is the PLP-60-48 designed for?
The PLP-60-48 is an LED power supply intended to be installed as a component inside LED lighting equipment. It is designed to drive LEDs directly in constant current mode, with a constant current region of 36 to 48V, rather than to feed additional drivers.
What input range does the Mean Well PLP-60-48 support?
This model supports a universal AC input range of 90 to 264VAC, and it also accepts 127 to 370VDC. That wide input range helps it fit projects used across different regional power systems.
Can the output current be adjusted on the PLP-60-48?
Yes. The spec sheet lists a current adjustment range of 0.975 to 1.3A, which is 75% to 100% of rated current. That gives some flexibility when matching the driver to the intended LED load within its rated design limits.
What protections are included in the Mean Well PLP-60-48?
The PLP-60-48 includes over current protection (constant current limiting at 100 to 110%), short circuit protection (hiccup mode, auto-recovery) and over voltage protection (57 to 63V, shuts down the output; re-power on to recover).
What operating environment is the PLP-60-48 rated for?
This model is rated for operation from -30°C to 70°C, with load derating at higher ambient temperatures according to the derating curve, and 20 to 95% RH non-condensing humidity. It is intended for use within that specified range.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.