Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLP-60-24 is the 24V output model of this series: rated current 2.5A, rated power 60W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Over current / Over voltage
- Built-in active PFC function
- Cooling by free air convection
- Class 2 power unit
- Output current level adjustable
- 100% full load burn-in test
- High reliability
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- CONSTANT CURRENT REGIONNote.5
- 18 ~ 24V
- RATED CURRENT
- 2.5A
- CURRENT RANGE
- 0 ~ 2.5A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 4.5Vp-p
- CURRENT ADJ. RANGE
- 1.875 ~ 2.5A
- VOLTAGE TOLERANCENote.3
- ±10%
- LINE REGULATION
- ±3.0%
- LOAD REGULATION
- ±5.0%
- SETUP TIME
- 500ms / 230VAC 1200ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.9 at 75 ~ 100% load, 115VAC / 230VAC
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≥75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 0.8A/115VAC 0.4A/230VAC
- INRUSH CURRENT (max.)
- COLD START 35A(twidth=55μs measured at 50% Ipeak) at 230VAC
- MAX.No. of PSUs on 16A CIRCUIT BREAKER
- 32units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENTNote.5
- 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 28 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- GB/T19510.1,GB/T19510.213 ,UL8750, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V) , EAC TP TC 004 approved ; design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to GB/T 17743, GB17625.1, BS EN/EN55015, BS EN/EN61000-3-2 Class C(≧75% load); BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 5065.8K hrs min. Telcordia SR-332 (Bellcore) ; 583.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 101.6*50.8*29.6mm (L*W*H)
- PACKING
- 0.16Kg; 96pcs/16.4Kg/0.89CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 5. Please refer to "DRIVING METHODS OF LED MODULE".
- 6. Heat sink HS1,HS2 can not be shorted.
- 7. Heat sink HS1 must have safety isolation distance with system case.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 11. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 12. PLP-60-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products(including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps) .
Technical drawings
Typical applications
- Suitable for built-in applications of LED lighting
- 2 years warranty
Downloads
Datasheet1
FAQ
What are the main electrical ratings of the Mean Well PLP-60-24?
The PLP-60-24 is a 60W single-output LED driver with a 24V output and a rated current of 2.5A. Its input range is 90 to 264VAC or 127 to 370VDC, which supports broad AC input compatibility. The spec sheet does not list a dimming function for this model.
What types of applications is the PLP-60-24 intended for?
The PLP-60-24 is an LED power supply intended to be installed as a component inside LED lighting equipment. It is best suited to LED loads that operate in its 18 to 24V constant current region and stay within the unit's 60W and 2.5A limits. For buyers comparing options, that makes it a fit for lighting equipment where a compact internal driver is needed.
Is the PLP-60-24 suitable for demanding operating temperatures?
This model has a specified operating temperature range of -30°C to 70°C, with load derating at higher ambient temperatures according to the derating curve. Storage is rated from -40°C to 80°C. That range makes it relevant for many indoor and protected equipment environments with wide ambient temperature swings.
What protection and reliability features does the PLP-60-24 include?
The PLP-60-24 includes short circuit (hiccup mode), over current (constant current limiting) and over voltage (28 to 35V) protection. Mean Well also specifies power factor correction with PF of 0.9 or higher at 75 to 100% load, and an MTBF of 583.3K hours min. (MIL-HDBK-217F, 25°C). These details help buyers prioritizing established safety and reliability features in a compact 60W driver.
How do I know if the PLP-60-24 is compatible with my 24V LED product?
The key compatibility check is whether your LED load operates within the 18 to 24V constant current region and does not exceed 2.5A or 60W. If your load needs more power or a different output voltage, this model is not the correct match. It is also important to note that the spec sheet lists no dimming function for the PLP-60-24, so it is intended for applications that do not require dimming control.
What distinguishes the PLP-60-24 from lower- or higher-power LED drivers?
The PLP-60-24 sits in the mid-range with a 60W output, which can make it a practical choice when smaller drivers do not provide enough capacity but a larger unit would be unnecessary. Its 24V, 2.5A output defines the loads it can support, so comparison should focus on required wattage, voltage, and current. Buyers also may value its lightweight 0.16 kg form factor for built-in lighting designs.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.