Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLM-12-1050 is the model of this series: rated current 1.05A, rated power 12.6W, typical efficiency 81%.
PLM-12 is a 12W economical AC/DC LED power supply series. Incorporating a built-in active PFC design, PLM-12 provides a high Power Factor value greater than 0.9. In addition, with the low no load power consumption below 0.5W, and the setup time less than 500ms, PLM-12 is complied with the ErP regulation required by European Union for lighting fixtures. PLM-12 is a class Ⅱ(without FG pin) power unit housed with the UL 94V-0 rated flame retardant plastic case. The I/O terminals are designed with screw-less clamp style terminal block that greatly simplifies the wiring installation.PL M-12 series, which operates from 110~295VAC.The series is constant current output design,supplying models with the current of 350mA, 500mA, 700mA and 1050mA, respectively.
Features
- Full range (up to 295VAC) models
- Built-in active PFC function
- Constant current design
- Protections:Short circuit
- Cooling by free air convection
- Fully isolated plastic case
- Class Ⅱ power unit, no FG
- Class 2 power unit
- No load power consumption <0.5W
- High reliability,low cost
- 2 years warranty
Specifications
OUTPUT
- CONSTANT CURRENT REGIONNote.5
- 7 ~ 12V
- RATED CURRENT
- 1.05A
- NO LOAD OUTPUT VOLTAGE(max.)
- 16V
- RATED POWER
- 12.6W
- RIPPLE & NOISE (max.)Note.2
- 1.8Vp-p
- CURRENT ACCURACYNote.3
- ±5.0%
- SETUP TIME
- 500ms / 115VAC, 230VAC at full load;
INPUT
- VOLTAGE RANGENote.4
- 110 ~ 295VAC 156 ~ 417VDC;
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≥0.97/115VAC,PF≥0.95/230VAC,PF>0.9/277VAC(at full load)(Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 81%
- AC CURRENT
- 0.15A/115VAC 0.08A/230VAC 0.07A/277VAC;
- INRUSH CURRENT(Typ.)
- COLD START 15A(twidth=50μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 160 units (circuit breaker of type B) / 160 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- 0.25mA / 240VAC
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +50℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.06%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- Ul8750, CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384, EAC TP TC 004,IP30 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms/500VDC / 25℃/ 70%RH
- EMC EMISSION
- Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C(≥60% load);BS EN/EN61000-3-3,EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61547, light industry level, criteria B(surge 2KV),EAC TP TC 020
OTHERS
- MTBF
- 7872.3K hrs min. Telcordia SR-332 (Bellcore) ; 598.9Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 145*38*22mm (L*W*H)
- PACKING
- 0.126Kg;60pcs/8.6 Kg/0.48CUFT
Certifications & ratings
- Input Voltage
- 110 ~ 295VAC
- Class
- Class Ⅱ
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Please see "AC input voltage drop vs. output current characteristics" table.
- 4. Derating may be needed under low input voltage, please check the static characteristic for more details.
- 5. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
- 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 8. The models certified by CCC (GB/T19510.1, GB/T19510.213, GB/T 17743 and GB17625.1) are optional models. Please contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Indoor LED lighting
- LED office lighting
- LED commercial lighting
- LED decorative lighting
Downloads
Certificates8
Test reports1
Catalogues1
FAQ
Can I use the PLM-12-1050 for a 1050mA LED downlight?
Yes, if the downlight is designed for constant current operation at 1050mA and its LED load falls within the 7-12V constant current range. This is a 12.6W constant current driver, so it is intended for LED loads that match that current requirement rather than constant voltage products.
Is the PLM-12-1050 suitable for LED signage modules?
It can be suitable for signage modules that require 1050mA constant current and operate within the 7-12V CC range. It is not the right match for constant voltage signage modules because this model regulates current, not fixed output voltage.
Can this driver run a small high-current LED array?
Yes, this model is suited to small LED arrays built for 1050mA constant current as long as the total forward voltage stays within 7-12V. With a 12.6W rating, it fits lower-voltage constant current arrays rather than larger higher-voltage assemblies.
How do I know if the PLM-12-1050 is compatible with my LEDs?
Check that your LEDs are specified for 1050mA constant current and that their combined forward voltage falls within the 7-12V CC output range. The number of LEDs depends on each LED's forward voltage, so there is no fixed LED count for this driver.
Is the PLM-12-1050 appropriate for cold or warm operating areas?
It is rated for operation from -30°C to +50°C, so it covers a fairly wide ambient range. The driver is a Class II design rated IP30, so it is meant for dry, protected locations and enclosure requirements should be considered for the final environment.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.