Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLG-600H-48 is the 48V output model of this series: rated current 12.5A, rated power 600W, typical efficiency 96%.
HLG-600H series is a 600W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-600H operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 96%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-600H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Standby power consumption <0.5W at remote off
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off)
- Typical lifetime > 62000 hours
- 7 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 24 ~ 48V
- RATED CURRENT
- 12.5A
- RATED POWER
- 600W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 40.8 ~ 50.4V
- CURRENT ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 6.2 ~ 12.5A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms/ 115VAC, 230VAC
- HOLD UP TIME (Typ.)
- 15ms / 115VAC, 230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
- EFFICIENCY (Typ.) 230VAC
- 96%
- EFFICIENCY (Typ.) 277VAC
- 96%
- AC CURRENT (Typ.)
- 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTION
- <0.5W at remote off
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 52.5 ~ 56.5V Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
FUNCTION
- REMOTE ON/OFF CONTROL
- Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
- 5V STANDBY
- 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)
- SAFETY STANDARDSNote.7
- UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB/T19510.1,GB/T19510.213, EAC TP TC 004, AS/NZS 60950.1(by CB),KC61347-1, KC61347-2-13(except for AB type) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.7
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T 17743,GB17625.1, KS C 9815, KS C 9547
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KS C 9815, KS C 9547
OTHERS
- MTBF
- 913.4K hrs min. Telcordia SR-332 (Bellcore) ; 76.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 280*144*48.5mm (L*W*H)
- PACKING
- 3.9Kg; 4pcs/16.6Kg/0.9CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The model certified for CCC(GB/T19510.1, GB/T19510.213, GB/T 17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
- 8. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 10. The driver is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type "HL" for use in ClassⅠ, Division 2 hazardous (Classified) location.
Downloads
Certificates6
Catalogues1
FAQ
Can I use the HLG-600H-48 to power large 48V LED strip installations?
Yes. The HLG-600H-48 outputs 600W at 48V and 12.5A, making it capable of driving long runs of 48V LED strip. For a strip rated at 15W/m, you could power up to 40 meters (600W / 15W per meter = 40m). Always check your strip's rated power per meter and keep total load at or below 600W.
Is the HLG-600H-48 a good fit for 48V LED high-bay warehouse lighting?
Yes. With 600W of capacity at 48V, it can power multiple 48V LED high-bay fixtures. The 48V output keeps cable currents lower than 24V alternatives, which reduces voltage drop over long cable runs in large warehouse spaces. Its IP67 rating also suits industrial environments with dust and moisture.
Can the HLG-600H-48 drive 48V LED modules for outdoor commercial signage?
Yes. At 600W and 48V it has enough capacity for large LED sign arrays. The IP67 waterproof rating and wide 90-305VAC input make it well suited for outdoor signs exposed to weather and varying mains voltages across different regions.
Is the HLG-600H-48 suitable for powering 48V LED landscape or pathway lighting?
Yes. Its 600W output can supply a substantial number of 48V landscape fixtures, and the IP67 waterproof rating handles direct ground-level rain and moisture exposure. The -40°C to +90°C case temperature (Tcase) range covers most climates year-round.
How many meters of 48V LED strip can the HLG-600H-48 handle?
Divide 600W by your strip's power consumption per meter. For example, a 48V strip rated at 10W/m allows up to 60 meters (600W / 10W per meter = 60m). A strip rated at 24W/m would allow 25 meters. Check your strip's rated power per meter and keep total load at or below 600W.
Can I install the HLG-600H-48 in a location fully exposed to rain and weather?
Yes. The IP67 waterproof rating means it can withstand temporary submersion and is fully protected against dust ingress. Combined with its -40°C to +90°C case temperature range and metal housing, it is designed for direct outdoor exposure without additional enclosures.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.