Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HBG-240-48DA is the 48V output model of this series: rated current 5A, rated power 240W, typical efficiency 93%.
HBG-240 series is a 240W AC/DC LED driver featuring the circular shape design. It operates from 90~305VAC and offers the dual modes constant voltage and constant current output models with different rated voltage between 24V and 60V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +75℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HBG-240 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Circular metal housing with classⅠdesign
- Built-in active PFC function
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.2
- 28.8 ~ 48V
- CONSTANT CURRENT REGION (for DA Type only)
- 33.6 ~ 48V
- RATED CURRENT
- 5A
- RATED POWERNote.5
- 240W
- RIPPLE & NOISE (max.)Note.3
- 250mVp-p
- CURRENT ADJ. RANGE
- 3 ~ 5A
- VOLTAGE TOLERANCENote.4
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms,120ms /230VAC 2500ms,120ms /115VAC
- HOLD UP TIME (Typ.)
- 15ms /115VAC, 230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load≧60%/115VC,230VAC; @load≧80%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section)
- EFFICIENCY (Typ.)Note.7
- 93%
- AC CURRENT (Typ.)
- 2.5A / 115VAC 1.3A / 230VAC 1.2A / 277VAC
- INRUSH CURRENT (Typ.)
- COLD START 75A(twidth=680μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 52 ~ 63V
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +75℃ (Please refer to " OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase=+75℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750,CSA C22.2 No.250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB/T19510.1,GB/T19510.213, BIS IS15885(for 48A,60A only), EAC TP TC 004, IP65 or IP67 approved
- DALI STANDARDS
- Compliance to IEC62386-101, 102, 207 for DA-Type only
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧75%) ; BS EN/EN61000-3-3, GB/T 17743, GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547,light industry level (surge immunity:Line-Earth:4KV, Line-Line:2KV), EAC TP TC 020
OTHERS
- MTBF
- 1792.9K hrs min. Telcordia SR-332 (Bellcore) ;172.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- ψ191.5mm *69mm (D * H)
- PACKING
- 2.1Kg; 8pcs/18.3Kg/2.09CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE".
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The DA type power supply is less efficient than the A type power supply by 1%.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build-in using or filling the Io adjusting hole with the potting compound to comply with Type HL application.
Technical drawings
Typical applications
- LED bay lighting
- LED stage lighting
- LED spot lighting
Downloads
Certificates8
Test reports1
FAQ
Can I use the HBG-240-48DA for a 48V high bay fixture?
Yes, this series is shown for high bay light installation and this model delivers 240W at 48V with a 33.6-48V constant current region. It fits fixtures that are designed for constant-current operation in that range and up to 5A output.
Is the HBG-240-48DA suitable for outdoor sign lighting?
It can be used for outdoor 48V constant-current signage lighting when the load is within the 33.6-48V range and does not exceed 240W. The series' IP65 or IP67 approval supports outdoor and wet-location use.
Can this driver power 48V canopy or exterior commercial lighting?
Yes, if the lighting load is a constant-current 48V system within the 33.6-48V operating window and up to 240W. The series' IP65 or IP67 approval and -40°C to +75°C working case temperature (Tcase) range make it suitable for exterior commercial lighting environments.
How much 48V LED strip can the HBG-240-48DA support?
Use the 240W maximum to estimate strip length: 240W divided by 12W per meter equals 20 meters, and 240W divided by 15W per meter equals 16 meters. Check your strip rated power per meter, and make sure the strip matches the 48V output or the 33.6-48V constant current region.
Is the HBG-240-48DA rated for rain and wet locations?
Yes, the HBG-240 series is IP65 or IP67 approved, so it is intended for outdoor and wet environments. The driver is also rated for a working case temperature (Tcase) of -40°C to +75°C, with load derating at higher temperatures, which helps in cold and hot exterior conditions.
What is the difference between the HBG-240-48DA and the other 240W HBG voltage versions?
In the 240W HBG range, the 24V models use a 14.4-24V or 16.8-24V constant current region, the 36V models use 21.6-36V or 25.2-36V, the 48V models use 28.8-48V or 33.6-48V, and the 60V models use 36-60V or 42-60V. The HBG-240-48DA is the 48V, 240W version with a 33.6-48V region, 5A output, and DALI interface.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.